Ferroli Prextherm N 107 Operating, Installation And Maintenance Manual
Ferroli Prextherm N 107 Operating, Installation And Maintenance Manual

Ferroli Prextherm N 107 Operating, Installation And Maintenance Manual

Advertisement

PREXTHERM N
HIGH-EFFICIENCY STEEL BOILER FOR LIQUID FUELS
ENGLISH
AND/OR GAS
OPERATING, INSTALLATION AND MAINTENANCE IN-
STRUCTIONS
CALDAIA IN ACCIAIO AD ALTO RENDIMENTO PER
ITALIANO
COMBUSTIBILI LIQUIDI E/O GASSOSI
ISTRUZIONI PER L'USO L'INSTALLAZIONE E LA
MANUTENZIONE
CHAUDIÈRE EN ACIER A HAUT RENDEMENT POUR
FRANÇAIS
COMBUSTIBLES LIQUIDES ET/OU GAZEUX
INSTRUCTIONS POUR L'INSTALLATION ET L'ENTRETIEN
HEIZKESSEL AUS GUSSEISEN MIT HOHEM WIRKUNGS-
DEUTSCH
GRAD FÜR FLÜSSIGE und/oder GASFÖRMIGE BRENN-
STOFFE
INSTALLATIONS-, BEDIENUNGS- UND WARTUNGSAN-
LEITUNGEN
CALDERA DE ACERO, DE ALTO RENDIMIENTO PARA
ESPAÑOL
COMBUSTIBLES LÍQUIDOS Y/O GASEOSOS
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENI-
MIENTO
CALDEIRA DE AÇO DE ALTO RENDIMENTO PARA COM-
PORTUGUÊS
BUSTÍVEIS LÍQUIDOS E/OU GASOSOS
INSTRUÇÕES PARA O USO, INSTALAÇÃO E MANUTEN-
ÇÃO
VERWARMINGSKETEL MET HOOG RENDEMENT VOOR
NEDERLANDS
VLOEIBARE en/of GASVORMIGE BRANDSTOF
AANWIJZINGEN VOOR HET GEBRUIK, DE INSTALLATIE
EN HET ONDERHOUD
STØBEJERNSFYR UDBYTTE TIL FLYDENDE BRÆND-
DANSK
STOF OG/ELLER GAS
INSTRUKTIONER VEDRØRENDE BRUG, INSTALLATION
OG VEDLIGEHOLDELSE
S›v› ve / veya gazl› yak›tlar için yüksek verimli çelik kazan
TÜRKÇE
Montaj, kullan›m ve bak›m k›lavuzu
Montaj, kullan›m ve bak›m k›lavuzu
Montaj, kullan›m ve bak›m k›lavuzu
Montaj, kullan›m ve bak›m k›lavuzu
Montaj, kullan›m ve bak›m k›lavuzu
Supplied By www.heating spares.co Tel. 0161 620 6677

Advertisement

Table of Contents
loading

Summary of Contents for Ferroli Prextherm N 107

  • Page 1 PREXTHERM N HIGH-EFFICIENCY STEEL BOILER FOR LIQUID FUELS ENGLISH AND/OR GAS OPERATING, INSTALLATION AND MAINTENANCE IN- STRUCTIONS CALDAIA IN ACCIAIO AD ALTO RENDIMENTO PER ITALIANO COMBUSTIBILI LIQUIDI E/O GASSOSI ISTRUZIONI PER L’USO L’INSTALLAZIONE E LA MANUTENZIONE CHAUDIÈRE EN ACIER A HAUT RENDEMENT POUR FRANÇAIS COMBUSTIBLES LIQUIDES ET/OU GAZEUX INSTRUCTIONS POUR L’INSTALLATION ET L’ENTRETIEN...
  • Page 2 PREXTHERM N Dear Customer, Thank you for having chosen the PREXTHERM N, an advanced-concept Ferroli ENGLISH boiler featuring cutting-edge technology, high reliability and constructional quality. Carefully read this manual and keep it for future reference. The PREXTHERM N is a high-efficiency heat generator for the production of hot water for heating purposes, suitable for operation with jet burners on gas or liquid fuel.
  • Page 3: Installation

    PREXTHERM N 1. OPERATING INSTRUCTIONS 1.1 Control panel 1 Ready for electronic control unit 2 Thermohydrometer 3 Safety thermostat 4 Control thermostat, 2 Stages 5 Line switch “0 - I - TEST” 6 Burner lockout indicator light fig. 1 1.2 Ignition Move the main switch 5 to position “I”...
  • Page 4: Water Connections

    PREXTHERM N 2.1 Water connections Make the water connections to the appliance according to the indications shown both next to each fitting and in Figure 2 of this booklet. The connections must be made in such a way that the pipes are not under stress. The safety valve must be fitted in the central heating circuit, as close as possible to the boiler, without there being any obstructions or on-off devices between the boiler and the valve.
  • Page 5: Flue Connections

    PREXTHERM N 2.4 Flue connections The boiler should be connected to a suitable flue, manufactured in compliance with the standards in force. The pipe between the boiler and the flue must be made from material suitable for this purpose, that is, resistant to both high temperatures and corrosion. The joints should be carefully sealed and the entire length of the pipe between the boiler and the flue should be thermally insulated, to avoid the formation of condensate.
  • Page 6 PREXTHERM N E Fasten the 2 front “side support brackets” “1”. F Position the sides. G Fasten the sides at the front “H1” and rear “H2” H Fit the wiring protection box “A” using the screws “B” on the sides, and position the pre-wired control panel. L Fit the cover or covers.
  • Page 7: Service And Maintenance

    All the adjustment, commissioning and maintenance operations must be performed by Qualified Personnel, in compliance with the standards in force. FERROLI S.p.A. declines all liability for damage to persons and/or things deriving from the tampering with the appliance by unqualified or unauthorised persons.
  • Page 8: Maintenance

    Heat input Water Operating Water Heat gas+oil pressure pressure content output (NHV) drop ∆t 10°C ∆t 20°C Model Prextherm N 107 Prextherm N 180 Prextherm N 300 Combustion chamber Dimensions Body weight Combustion chamber Ø1 Ø2 Ø3 load loss Ø Lenght Volume ∆p mbar...
  • Page 9 PREXTHERM N fig. 4 fig. 5 Pump (not supplied) Auxiliary contact Safety thermostat Boiler setting thermostat, 1 stage Room thermostat (not supplied) Boiler setting thermostat, 2 stage Switch Lockout indicator light (not supplied) Water pressure Switch Burner connector Test knob Note The dashed sections of wiring are the responsibility of the installer Supplied By www.heating spares.co Tel.

This manual is also suitable for:

Prextherm n 180Prextherm n 300

Table of Contents