iring diagram
Fig. D-3
Flag terminal
Set Flag terminal to Switch
as shown above.
Stator complete
Thick lead wires from Stator complete
must be put on the other thin lead wires
for the designated area .
Lead wires from Stator complete must be
routed between Boss A and Rib C.
Lead wire (Red) from Terminal must be;
• placed under Lead wires from Stator complete
• routed between Rib D and Rib E.
The slack of Lead wire (Red) from
Terminal must not be piled on/under
Capacitor of Controller.
Lead wires from Terminal must be
placed under Rib of Controller.
Switch
Lead wire
(white)
Boss A
Rib of Controller
Rib D
Capacitor of Controller
Rib C
Boss B
Do not put any lead wires
on these ribs.
Rib E
Controller
Rib E
Terminal