Download Print this page

On/Off Switch - Peavey RBN 215 SUB Operating Manual

Powered speaker system

Advertisement

LOWER REAR PANEL
1
2
T10AH/250V
220-240V
T5AH/250V
3
ON-OFF SWITCH (1)
This rocker switch supplies AC power to the RBN™215 when switched to the ON position. The ON position is
with the top side of the switch pushed "in" or nearly flush with the rear panel.
FUSE (2)
The unit is AC power line fuse protected from overloads and fault conditions with a slow-blow 5 x 20mm
250V fuse. This fuse is located within the cap of the fuse holder. If the fuse fails, THE FUSE MUST BE RE-
PLACED WITH THE SAME TYPE AND VALUE IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT
AND TO PREVENT VOIDING THE WARRANTY!
The fuse in the RBN™215 Sub can be replaced with a time-delay type 5 x 20 mm size 250V rated fuse.
For 120VAC operation, a fuse rated at 10 amps should be used. In the USA, types GDC, GMC, 215, 218, and 477
cartridge-style 5 x 20 mm size fuses with a 10 amp 250V rating can be used.
For 220-240VAC operation, a fuse rated at 5 amps and 250V should be used, which conforms to the internation-
al fuse classification "T5AH".
If the unit continues to blow replacement fuses, do not keep replacing them, it should be taken to a qualified
service center for repair. To replace the fuse, be sure to remove the IEC power cord from the IEC socket.
IEC POWER CORD CONNECTION (3)
This receptacle is for the IEC line cord (supplied) that provides AC power to the unit. It is very important
that you ensure the RBN™215 has the proper AC line voltage supplied. You can set the proper voltage for your
RBN™215 using the Voltage Selector switch (4) on the rear panel of the unit.
WARNING:
SHOULD NOT BE EXPOSED TO RAIN OR MOISTURE AND OBJECTS FILLED WITH LIQUIDS,
SUCH AS VASES, SHOULD NOT BE PLACED ON THIS APPARATUS. TO PREVENT THE
RISK OF FIRE HAZARD, REPLACE WITH SAME TYPE 250 VOLT FUSE.
AVIS:
DANS LE BUT DE REDUIRE LES RISQUES D'INCENDIE OU DE DECHARGE
ELECTRIQUE, CET APPAREIL NE DOIT PAS ETRE EXPOSE A LA PLUIE OU A L'HUMIDITE ET
AUCUN OBJET REMPLI DE LIQUIDE, TEL QU'UN VASE, NE DOIT ETRE POSE SUR CELUI-CI.
REMPLACER PAR UN FUSIBLE DE MEME TYPE ET DE 250 VOLTS.
CAUTION
AVIS:
RISQUE DE CHOC
ELECTRIQUE-NE PAS OUVRIR
ON
POWER
FUSE
120V
FUSE
FUSE
AC Cable
50/60Hz
200 WATTS
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
Consumo de energia
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
200Wh
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, THIS APPARATUS
Designed and Engineered in U.S.A.
Made in China
FOR 220-240V OPERATION, FUSE
MUST BE CHANGED TO T5AH/250V
220-240V
120V
FOR 120V OPERATION, FUSE
MUST BE CHANGED TO T10AH/250V
CAN-ICES-3(B)/NMB-3(B)
- - Laite on liitettävä suojamaadoituskoskettimilla
varustettun pistorasiaan. (For Finland only)
- - Apparatet må tilkoples jordet stikkontakt.
(For Norway only)
- - Apparaten skall anslutas till jordat uttag.
(For Sweden only)
4

Advertisement

loading