FT010AB Series Installation & Operation Manual Installation and Operation Manual FT010AB Series Digital Series 1-Ch Bi-directional Audio Fiber Optic Converter OT Systems Ltd., 2014 Rev 1.2 www.ot-systems.com...
FT010AB Series Installation & Operation Manual (1) Safety Instructions Please be familiar with all information in this manual prior to installation and operation. Note 1: The products described contain a Class 1 laser or LED fiber optic emitter. The following safety precautions apply.
FT-PA/12V, which can be powered by local 110/220V power. The FT010AB Series units are also available as plug-in card modules installed in a 19” rack-mount chassis. Each plug-in card occupies one slot in the rack-mount chassis. The rack mount chassis has to be ordered separately, and comes with its own power supply for powering the installed card modules.
The Standalone unit works with an external power supply FT-PA/12V powered by local 110/220V power. The FT010AB Series card modules are housed inside the FT-C18 rack-mount chassis (Fig. 3.2) with an included power supply unit. The whole chassis is powered by local 110/220V power.
FT010AB Series Installation & Operation Manual 3.3 Card module installation Insert the card module into the FT-C18 chassis along the top and bottom card guides of an empty slot and push the card into the multi-pin socket at the rear firmly. Secure with the provided thumb screws.
Page 9
FT010AB Series Installation & Operation Manual Standalone Transmitter Card Module Receiver Fig. 4.2 Standalone unit to Card Module connection diagram Card Module Transmitter Card Module Receiver Fig. 4.3 Card Module to Card Module connection diagram www.ot-systems.com...
FT010AB Series Installation & Operation Manual 4.2 Audio port assignment and pin connections For audio input and output connections, please note the following pin assignment: Pin Assignment (Screw Terminal Block) Data format Balanced signal IN (+) IN(-) OUT(+) OUT(-) Un-Balanced signal Sig.
FT010AB Series Installation & Operation Manual 4.3 Ground connection For enhanced safety to reduce the risks of electrical shock and physical damage, caused by lightning and other power surges, as well as a connection to the surge suppresion devices in the product, a screw terminal is provided on the Standalone cabinets (Fig.
FT010AB Series Installation & Operation Manual (5) Operational Guides 5.1 FT010AB Series Transmitter LED Indicators Indicator Color Description Lit when power is supplied to the Transmitter. Yellow Lit when optical signal from receiver to transmitter is active.* a) Each audio channel has a single column of Four LEDs assigned for displaying the input or output audio levels.
FT010AB Series Installation & Operation Manual (7) Drawings Fig. 7.1 Dimensional drawings of Standalone unit (mm) (8) Warranty Information All OT Systems FT Series products are subject to a limited life-time warranty offered by the company in normal circumstances. Please refer to the OT Systems Products Warranty Statement for details.