Installation Preparation; Hanging Bracket Installation - Ellington LAV52BP4-NRG Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

3. Installation Preparation.

To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a downrod
on a regular (no-slope) or vaulted ceiling. The
hanging length can be extended by purchasing
a longer downrod (0.5in./1.27cm diameter).
Other installation such as flushmount is not
available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.

4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch is
turned to the OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure
the outlet box is securely attached to the building
structure and can support the full weight of the fan.
Ensure outlet box is clearly marked "Suitable for Fan
Support." If not, it must be replaced with an approved
outlet box. Failure to do so can result in serious injury.
CAUTION: Be sure outlet box is grounded properly and
that a ground wire (GREEN or bare) is present.
Install hanging bracket to outlet box using original
screws, spring washers and flat washers provided with
new or original outlet box.* If installing on a vaulted
ceiling, face opening of hanging bracket towards high
point of ceiling. Arrange electrical wiring around the
back of the hanging bracket and away from the
hanging bracket opening.
*Note: It is very important that you use the proper
hardware when installing the hanging bracket as this
will support the fan.
blade edge
30
inches
7 feet
(76 cm)
(2.13m)
downrod
installation
hanging bracket
flat washers
outlet box screws
page 3
12 ft. - 20 ft.
(3.66 m - 6.1 m)
flushmount
installation
Vaulted ceiling
angle is not to
exceed 25 degrees.
spring washers