7.0 TROUBLESHOOTING
PROBLEM
Sporadic Tool Action:
Motor Will Not Start:
Noisy Operation:
Pump Oil is Over Heating:
Pump Runs But Will Not Pump Oil:
••• 7 •••
CAUSE-SOLUTION
•
Air in the hydraulic system. Bleed the hydraulic circuit.
•
Check reservoir oil level.
•
Be sure power cord is not damaged.
•
Check for tripped circuit breaker; be sure breaker is of adequate
size.
•
Have motor checked for proper operation.
•
Have qualified electrician inspect for loose or faulty wiring or switch.
•
Air in system.
•
Be sure the oil reservoir is filled to normal level.
•
Check all points where air might leak into system.
•
Clogged or blocked intake screen.
•
Inspect for high pressure leakage at the pump (leaking at plug or
relief valve).
•
Oil level is low. Fill reservoir to normal level, or retrofit the pump with
larger reservoir or heat exchanger.
•
Pump is not primed. Run pump a few minutes tipping from side to
side.
•
Inspect to make sure that external adjustable relief valve is set
properly.
•
Defective control valve, take to nearest Simplex Authorized Service
Center for repair.
•
Incorrect motor rotation, take to nearest Simplex Authorized Service
Center for repair.
•
Check to make sure the intake screen is not clogged. Clean if
needed.
•
Check oil reservoir is low. Fill as needed.
•
Oil viscosity is too high. Replace with SIMPLEX oil.