(2) Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents
produced by equipment connected to public low-voltage systems with input current \>16A and ≤ 75A per phase
(3) PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
(4) European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A
and ≤ 75A per phase.
(5) Short-circuit power
(6) RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
(7) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).