A C And Effectiv E V Alue Measurement; Resistance Measurement (Ch1); Current Measurement (Ch1 And Ch2); Continuity Tester (Ch1) - Bosch KTS 530 Operator Instructions Manual

Hide thumbs Also See for KTS 530:
Table of Contents

Advertisement

en
24 | KTS 530 / KTS 540 / KTS 570 | Tech nical data
5.4.2

A C and effectiv e v alue measurement

(CH1 and CH2)
* )
Property
Frequency range AC
Measurement range
AC precision at 100 Hz
EFF precision at ≤ 100 Hz
Resolution
*)
T h e m easurin g ran g es an d ty p es of m easurem en t "U " an d "I" are
p eak -to-p eak v alues. T h is results in th e d ig ital d isp lay field bein g
g ray ed out as soon as th e d efin ed m easurin g ran g e h as been
ex ceed ed for a sh ort tim e (O v erload ).
5.4.3

Resistance measurement (CH1)

Property
Measurement range
Precision up to 200 K
Precision up to 1 M
Resolution
Input resistance
5.4.4

Current measurement (CH1 and CH2)

sensor
Shunt (CH1 only)
30 A clamp (CH1 only)
100 A clamp
600 A clamp
1000 A clamp (CH1 only)
5.4.5

Continuity tester (CH1)

Property
Measurement current
Open circuit voltage
Continuity
5.4.6

Diode measurement (CH1)

Property
Measurement current
Open circuit voltage
Maximum diode voltage
1 689 979 987
|
2006-09-29
Value/Range
10 Hz — 400 Hz (-3 dB)
200 mV — 200 V
±2 % of measurement
value, additional
±0.5 % of measurement range
100 V — 100 mV
(depending on measuring range)
Value/Range
100
— 1 M
±0.75 % of measurement value
additional ±0.25 % of
measurement range
±2 % of reading
additional ±0.25 % of
measurement range
0.1
— 1000
(depending on measuring range)
> 9 M
Measurement range
±600 mA
±30 A
±100 A
±600 A
±1000 A
Value/Range
2 mA
≤ 5 V
< 10
(with acoustic response)
Value/Range
2 mA
≤ 5 V
2 V
5.5
Oscilloscope specifications
CH1 and CH2 are potential based
(Measuring input CH1(–) or measuring input
ground must be connected to the vehicle ground).
Input resistance > 900 kOhm.
Property
Value/Range
Measurement range
0 — 200 V
DC, AC,
Coupling
DC(+) (only positive range is shown),
DC(-) (only negative range is shown).
U, 30 A (CH1 only), 100 A,
600 A, 1000 A (CH1 only),
Signal source
Diagnosis pins 1 to 15
(not pins 4, 5)
X -deflection
50 s — 1 s
Trigger mode
Manual, Auto-Time, Auto-Level
Trigger source
CH1, CH2
Pretrigger time
0 — 80 %
Frequency range
> 1 MHz (typical 5 MHz)
50 signal curves with
Memory depth per channel
512 coordinates
5.6

B luetooth Class 1

W ireless connection
KTS 540, KTS 570 to PC/L aptop
Workshop environment in the open
space
If the vehicle door or window is open
and the engine is still running in the ve-
hicle interior
Minimum range
30 meters
10 meters
Bosch Diagnostics
http://www.obd2be.com/

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kts 540Kts 570

Table of Contents