Maintenance; Cleaning; S Pare And W Earing Parts; Tec H Nic A L D A Ta - Bosch KTS 530 Operator Instructions Manual

Hide thumbs Also See for KTS 530:
Table of Contents

Advertisement

4.
M a in t e n a n c e
4.1

Cleaning

The housing of the KTS modules are only to be cleaned
using a soft cloth and a neutral cleaning agent. Do not
use any abrasive cleaning agent or rough cleaning cloths.
4.2

Maintenance

Cu stom er serv ice
The tab
various tests in DDC. A portion of these tests can only
be performed by customer service.
4.3

S pare and w earing parts

R eplacement and wear parts only concern parts
received in the respective delivery.
Des cription
System tester KTS 5 3 0
System tester KTS 5 4 0
System tester KTS 5 7 0
Adapter insert
OBD diagnosis cable 3 m (KTS 5 3 0 )
OBD diagnosis cable 1 .5 m (KTS 5 4 0 /5 7 0 )
Power pack
Power supply cable
(<)
M easuring cable blue (KTS 5 3 0 /5 4 0 )
M easuring cable yellow (KTS 5 3 0 /5 4 0 )
(<)
G round cable black
M easuring cable red/black (KTS 5 7 0 )
M easuring cable blue/yellow (KTS 5 7 0 )
Test tip red (1 x , with KTS 5 7 0 2 x )
Terminal clip black
(<)
Connection cable USB 3 m
(<)
UN I connection cable 4 core
(<)
Case
M ount parts set
Bluetooth USB adapter (KTS 5 4 0 /5 7 0 )
(<)
P a r t s u b je c t to w e a r
Bosch Diagnostics
can be used for performing
Ord er Num b er
1 6 8 7 0 2 2 4 3 7
1 6 8 7 0 2 2 4 3 6
1 6 8 7 0 2 2 9 9 4
1 6 8 8 0 0 0 3 4 9
(<)
1 6 8 4 4 6 5 5 5 7
(<)
1 6 8 4 4 6 5 5 5 5
1 6 8 7 0 2 2 8 8 9
1 6 8 4 4 6 1 1 0 6
(<)
1 6 8 4 4 3 0 0 6 6
(<)
1 6 8 4 4 3 0 0 6 7
1 6 8 4 4 3 0 0 6 8
(<)
1 6 8 4 4 6 3 2 1 4
(<)
1 6 8 4 4 6 3 5 5 0
1 6 8 4 4 8 5 0 3 5
1 6 8 4 4 8 0 0 2 2
1 6 8 4 4 6 5 5 6 2
1 6 8 4 4 6 3 5 3 9
1 6 8 5 4 3 8 1 4 5
1 6 8 7 0 0 1 8 5 3
1 6 8 7 0 2 3 3 8 2
Maintenance | K TS 5 30 / K TS 5 40 / K TS 5 7 0 | 23
5 .
T e c h n ic a l d a t a
5 .1

G eneral d ata

Property
Operating voltage
Power consumption through
vehicle battery or power supply
Dimensions (L x W x H)
W eight (without connecting cables)
Operating temperature
R elative humidity
5 .2

Interface protocols

The following interfaces with respective protocols are
supported for controller diagnosis in conformance with
ISO 1 5 0 3 1 :
ISO 9 1 4 1 -2 (Communications lines K and L)
SAE J 1 8 5 0 V PW and SAE J 1 8 5 0 PW M
(Communication lines BUS+ and BUS-)
CAN ISO 1 1 8 9 8 ISO 1 5 7 6 5 -4 (OBD)
(Communication lines CAN -H and CAN -L)
CAN Single W ire
CAN Low Speed
5 .3

Pow er pack

Property
Input voltage
Input frequency
Output voltage
Operating temperature
5 .4
Multim eter s pecifications
CH1 zero potential (blue input is not allowed to be
connected with voltage carrying measuring points).
Input resistance > 9 0 0 k Ohm.
CH2 potential based (black ground input
must be connected with vehicle ground).
Input resistance > 9 0 0 k Ohm.
5 .4.1

DC m eas urem ent (CH1 and CH2)

Property
V alue/ R ange
M easurement range
2 0 0 mV — 2 0 0 V
± 0 .7 5 % of measurement value,
Precision CH1
additional ± 0 .2 5 % of measurement range
± 2 % of measurement value,
Precision CH2
additional ± 0 .5 % of measurement range
1 0 0
R esolution
(depending on measuring range)
V alue/ R ange
7 V DC — 3 0 V DC
approx . 6 W att
1 7 0 x 1 2 0 x 4 0 mm
3 2 5 g
0 ° C – 4 0 ° C
9 0 % (at 2 5 ° C)
V alue/ R ange
9 0 — 2 6 4 V AC
4 7 — 6 3 Hz
1 5 V
0 ° C — 4 0 ° C
V — 1 0 0 mV
1 6 8 9 9 7 9 9 8 7
|
2 006 -09 -2 9
http://www.obd2be.com/