12D-SFA-CV (100)
Dimensions in millimeters.
Outer Sheath
Armor
Inner Sheath
80
Nut
Gasket
Washer
Clamp Nut
Solder through
the hole.
Shield
Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
12
Twist shield end.
Slip on clamp nut, gasket and clamp as shown left.
Clamp
1.8
Expose the insulator by 1.8 mm.
Expose the core by 4.5 mm.
4.5
Pin
Slip the pin onto the conductor. Solder them
together through the hole on the pin.
Insert the pin into the shell. Screw the clamp
nut into the shell.
(Tighten by turning the clamp nut. Do not
tighten by turning the shell.)
How to fabricate antenna cable 12D-SFA-CV
10