Technical data

Heater
EC licensing symbol
Model
Heat output
Fuel
Fuel consumption
Rated voltage
Operating voltage range
Nominal power consumption with circulation
pump (without vehicle fan)
Max. ambient temperature:
Heater:
- Operation
- Storage
Control module:- Operation
- Storage
Metering pump: - Operation
- Storage
Max. operating pressure (heat medium)
Capacity of the heat exchanger
Max. combustion air intake temperature
Minimum capacity of the system
Delivery rate of the circulating pump against
0.15 bar
CO
in the exhaust fumes
2
(normal function range)
CO
- adjustment values at approx. + 20 °C
2
and geographic altitude above sea level
Heater dimensions (tolerance ± 3 mm)
* Control module installed on the heater
Weight
66
Visit www.butlertechnik.com for more technical information & downloads.
Operation
Thermo 90 S / ST
00 0005* / 00 19*
Max.
regulating
2.0 kW – 7.6 kW
range
Max. regu-
lating range
0.25 l/h – 1.0 l/h
Max. regu-
lating range
37 W - 83 W
-40° ... +75 °C
-40° ... +20 °C
Max.
Max.
Max.
L 310 (355*) / 307(352*) mm
www.butlertechnik.com
Thermo 90 S / Thermo 90 ST
Thermo 90 S diesel
Petrol
Thermo 90 S-ADR
00 0005*
Water heater with Ferro-tec technology
Petrol
12 V
10 ... 15 V
-40° ... +110 °C (90 °C with control module installed on the heater)
-40° ... +110 °C (90 °C with control module installed on the heater)
-40° ... +75 °C
-40° ... +85 °C
-40° ... +85 °C
2.0 bar
0.15 l
+40 °C
6.00 l
1650 l/h
10 ... 12.0 % by volume
0 m
500 m 1000 m
10 %
10.6 %
L 310 (355*) mm
W 131 mm
W 131 mm
H 232 mm
H 232 mm
4.8 kg
Thermo 90 ST diesel
Thermo 90 ST-ADR
9.1 kW
1.8 kW – 7.6 kW
Diesel
1.1 l/h
0.19 l/h – 0.9 l/h
12 or 24 V
10 ... 15 or 20 ... 30 V
90 W
37 W - 83 W
-40° ... +85 °C
-40° ... +40 °C
11.3 %
L 307 (352*) mm
W 131 mm
H 232 mm