Electrical Wiring - Dunkirk XEB-2 Installation, Operation & Maintenance Manual

Gas-fired hot water induced draft boiler
Table of Contents

Advertisement

Table 8a - NATURAL GAS
Pipe Capacity - BTU Per Hour Input
Length
of
Pipe - Ft.
½"
20
92,000
40
63,000
60
50,000
Table 8b - PROPANE GAS
Pipe Capacity - BTU Per Hour Input
Length
of
Copper Tubing*
Pipe - Ft.
⅝"
20
131,000
40
90,000
60
72,000
*Outside diameter:
The length of pipe or tubing should be measured from the gas
meter or propane second stage regulator.
All electrical work must conform to the requirements of
the authority having jurisdiction or, in the absence of such
requirements, with the National Electrical code, ANSI/NFPA
70, and/or the Canadian Electrical Code Part I, CSA C22.1,
Electrical Code
Electrical shock hazard. Turn OFF electrical
!
power supply at service panel before making
electrical connections. Failure to do so could
result in death or serious injury.
Electric Power Supply
Run a separate 115 volt circuit from a separate over
current protective device in the electrical service entrance
panel. This should be a 15 ampere circuit. Locate a shut-
off switch at the boiler. It must be turned off during any
maintenance. Connect 115 volt power supply to aquastat
terminals L1 (HOT) and L2.
The boiler, when installed, must be electrically bonded
to ground in accordance with the requirements of the
authority having jurisdiction or, in the absence of such
requirements, with the National Electrical code, ANSI/NFPA
70, and/or the Canadian Electrical Code Part I, CSA C22.1,
Electrical Code. Run a 14 gauge or heavier copper wire
from the boiler to a grounded connection in the service
panel or a properly driven and electrically grounded ground
rod.
Includes Fittings
¾"
1"
190,000
350,000
625,000
130,000
245,000
445,000
105,000
195,000
365,000
Includes Fittings
Iron Pipe
¾"
½"
216,000
189,000
393,000
145,000
129,000
267,000
121,000
103,000
217,000
WARNING
gAS SuppLy pIpINg
1¼"
¾"

ELECTrICAL WIrINg

Label all wires prior to disconnection when
!
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
Install Your Thermostat
The thermostat location has an important effect on the
operation of your boiler system. BE SURE TO FOLLOW
THE INSTRUCTIONS INCLUDED WITH YOUR THERMOSTAT.
Locate the thermostat about five feet (5') above the floor
on an inside wall. It may be mounted directly on the wall
or on a vertically mounted outlet box. It should be sensing
average room temperature.
THERMOSTAT LOCATIONS TO AVOID
DEAD
SPOTS
Behind
doors
Corners &
alcoves
Set heat anticipator at .2 amps. The 24 volt thermostat
connects to aquastat terminals T and T.
20
CAUTION
HOT SPOTS
COLD SPOTS
Concealed pipes
Concealed pipes
Fireplace
TV sets
Stairwells - drafts
Radios
Doors - drafts
Lamps
Unheated room on
Direct sunlight
other side of wall
Kitchens
or ducts