Error Code
Problem
12
SSR too hot
13
Generator too hot
14
fan running too slow
16
IO board too hot
19
Internal defect
20
Internal defect
21
Invalid program
22
programme interrupted
24
Draining failure
25
ClimaOptima
TROUBLESHOOTING
Possible solution
The solid-state relay is too hot. Clean
the inlet filter at the bottom of the panel.
Contact authorized service personnel.
The temperature of the steam generator
is higher than 130°C. If the error recurs,
contact authorized personnel to descale.
Check inlet filter at the bottom of
the panel. If the error recurs, contact
authorized service personnel.
Contact authorized service personnel.
An internal software error occurred.
Restart the oven.
A communication failure occurred
between the computer and the IO board.
Contact authorized service personnel.
you have chosen a program that is not
supported by the oven.
A program in progress was interrupted
because of a power supply interruption.
The power supply interruption lasted
so long that the program cannot be
restarted.
The steam generator could not be
emptied during flushing. The level
sensor reports high water level when the
generator is emptied. Contact authorized
service personnel.
The ClimaOptima function has not been
calibrated. Go to the service menu to
calibrate.
STANDARD USER MANUAL 27
Need help?
Do you have a question about the Visual Cooking C and is the answer not in the manual?