30
6.2.2

Cleaning work

Unit component
Centrifuge
Droplet trap
Mat holder
Base tub cover
Base tub
Flock-coated evaporator mat
(activated carbon evaporator mat)
Air intake and air outlet lattices
Coarse filter
Coarse dust filter (or Quattro filter,
respectively
What to clean and how to clean
• Wash parts with a lukewarm soap solution and rinse
well with tap water. Additionally clean the centrifuge
inside with the brush supplied.
• Occasionally remove scale coating with a household
decalcify agent (observe safety notes in chapter 6.6).
Finally rinse the parts well with tap water.
• Rinse the evaporator mat thoroughly with lukewarm
water without any additives.
Note: As soon as the filter replacing message appears
in the display (see error messages in chapter ) replace
the evaporator mat together with the filters.
• Clean the air intake and air outlet lattices on both sides
with a vacuum cleaner.
• Clean coarse filter on the air inlet side and the coarse
dust filter (or the Quattro filter) on the inner side with a
vacuum cleaner (lowest power step).
Note: As soon as the filter replacing message appears
in the display (see error messages in chapter ) replace
coarse filter, coarse dust filter (Quattro filter) together
with the evaporator mat.
Make sure the filters do not get wet. Wet
CAUTION!
filters must be dry before reinstalling.