Different corridor widths can be set for the
boundary wire, guide 1 and on guide 2. The
default setting on Automower
19 for both the boundary wire and guide wires.
The higher the stated Corridor width value, the
less risk there is of tracks forming. However, a
high corridor value means that Automower
find it difficult to enter passages.
A garden with large open areas should have a
wide Corridor, i.e. a high Corridor width value.
A garden with passages should have a narrow
Corridor, i.e. a low value for the Corridor width.
When the value is set to 0 for the Corridor width,
Automower
®
will run along the boundary wire,
which means it will run with half the mower inside
the loop and half the mower outside. As there are
often flower beds, hedges and walls along with
the boundary wire Corridor width 0 is not
normally recommended. Should you still like to
state this value, the boundary wire must lay
50 cm from solid objects instead of the normal
40 cm.
IMPORTANT INFORMATION
The distance at which the mower follows the
boundary wire varies depending on how the
working area appears. You should perform
some tests to find the highest possible
Corridor width. Use the Test IN (3-2-4)
function to try different values.
Test IN (3-2-4)
The Test IN (3-2-4) function is used to test how
Automower
®
finds its way into the charging
station.
58 - English
6. MENU FUNCTIONS
Follow loop out
®
is set to a value of
Follow loop in
Corridor width
®
may
Test IN
Test OUT
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT
Boundary corridor
Guide 1 corridor
Guide 2 corridor
3-2-3
3-2-4
3012-912