Start In/Shutdown Instructions; Starting The Engine; Stopping The Engine; Break-In Period - Lincoln Electric RANGER 10,000 PLUS Operator's Manual

For machines with code number 11394, 11395, 11398
Hide thumbs Also See for RANGER 10,000 PLUS:
Table of Contents

Advertisement

B-3
STARTING/SHUTDOWN INSTRUCTIONS

STARTING THE ENGINE

• Do not touch electrically live parts
• Keep flammable material away.
Be sure all Pre-Operation Maintenance has been per-
formed. Also, read the Engine Owner's Manual before
starting for the first time .
Remove all loads connected to the AC power recepta-
cles. Use the choke control as follows:
KOHLER ENGINE - Always pull the choke control out
when starting the engine; cold, warm or hot.
SUBARU ROBIN - If the engine is cold or the temper-
ature is low pull the choke out fully. If the engine is
warm or temperature is high, pull choke half out or
leave in completely.
HONDA ENGINE - If the engine is cold, pull the choke
control out. Do Not use the choke if the engine is
warm or hot.
Turn the engine switch to the "start"
crank the engine until it starts. Release the switch as
soon as the engine starts, slowly return the choke
control to the full "in" position (choke open),
and turn the switch to the Auto Idle(
position. Do not turn the switch to the "start" position
while the engine is running because this will cause
damage to the ring gear and/or starter motor
Downloaded from
www.Manualslib.com
WARNING
of electrode with skin or wet
clothing.
• Insulate yourself from work and
ground. Wear eye, ear, and body
protection.
• Keep your head out of the fumes.
• Use ventilation or exhaust to
remove fumes from breathing zone.
position and
RANGER 10,000 PLUS AND RANGER 10,000
manuals search engine
OPERATION
After running at high engine speed for 10-14 seconds,
the engine will go to low idle.
Allow the engine to warm up by letting it run at low idle
for a few minutes.

STOPPING THE ENGINE

Remove all welding and auxiliary power loads and
allow engine to run at low idle speed for a few minutes
to cool the engine.
Stop the engine by placing the Engine switch in the
"OFF"
A fuel shut off valve is not required on the RANGER
10,000 PLUS AND RANGER 10,000 because the fuel
tank is mounted below the engine.

BREAK-IN PERIOD

It is normal for any engine to use a greater amount of
oil until the break-in is accomplished. Check the oil
level twice a day during the break-in period (approxi-
mately 50 running hours).
IMPORTANT: IN ORDER TO ACCOMPLISH THIS
KOHLER
CH23S
5 HRS.
The engine manufacturer's recommendation for the
running time until the first oil change is as follows:
The oil filter is to be changed at the second oil
change. Refer to the Engine Owner's Manual for more
information.
/
)
position.
BREAK-IN, THE UNIT SHOULD BE
SUBJECTED TO MODERATE
LOADS, WITHIN THE RATING OF
THE MACHINE. AVOID LONG IDLE
RUNNING PERIODS. REMOVE
LOADS AND ALLOW ENGINE TO
COOL BEFORE SHUTDOWN.
SUBARU ROBIN
EH65
25 HRS.
B-3
HONDA
GX620KI
25 HRS.
or 20 HRS.