EAGLE™ 10,000 PLUS
EAGLE™ 10,000 PLUS APPROXIMATE FUEL CONSUMPTION
CONDITION
High Idle
Low Idle
210A @ 25V
9000 Watts
STARTING/SHUTDOWN INSTRUCTIONS

STARTING THE ENGINE

WARNING
Do not touch electrically live parts of
electrode with skin or wet clothing.
Insulate yourself from work and ground.
Wear eye, ear, and body protection.
Keep your head out of the fumes.
Use ventilation or exhaust to remove fumes
from breathing zones.
Be sure all Pre-Operation Maintenance has been performed. Also,
Remove all loads connected to the AC power receptacles. Use the
choke control as follows:
- ALWAYS pull the choke control out when starting the engine;
cold, warm or hot.
1) Turn the engine switch to the "start"
the engine until it starts. Release the switch as soon as the
engine starts, slowly return the choke control to the full "in"
position (choke open), and turn the switch to the Auto Idle
(
) position. Do not turn the switch to the
"Start" position while the engineis running because this will
cause damage to the ring gear and/or starter motor.
GV750™
GAL/HR
0.83
0.47
1.52
1.70
3) After running at high engine speed for 10-14 seconds, the
engine will go to low idle.
4) Allow the engine to warm up by letting it run at low idle for
a few minutes.

STOPPING THE ENGINE

Remove all welding and auxiliary power loads and allow engine
to run at low idle speed for a few minutes to cool the engine.
Stop the engine by placing the Engine switch in the "OFF"
position.
A fuel shut off valve is not required on the EAGLE™ 10,000
Plus because the fuel tank is mounted below the engine.

BREAK-IN PERIOD

It is normal for any engine to use a greater amount of oil until the
break-in is accomplished. Check the oil level twice a day during
the break-in period (approximately 50 running hours).
NOTE: IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE UNIT
SHOULD BE SUBJECTED TO MODERATE LOADS, WITHIN THE
RATING OF THE MACHINE. AVOID LONG IDLE RUNNING
PERIODS. REMOVE LOADS AND ALLOW ENGINE TO COOL
BEFORE SHUTDOWN.
The engine manufacturer's recommendation for the running time
the engine service information in this manual for more
information.
position and crank
B-2
OPERATION
LITERS/HR
3.13
1.79
5.77
6.44
LINCOLN
GV750™
10 HRS