Pro Series, JXi
®
6.1

Service Access

Remove the four screws holding
the front heater panel in place to
expose the raceway.
a
Locate the raceway lock
release on the interior of the
heater raceway.
b
Using a screwdriver or
comparable tool; press into the
raceway release orifi ce until the
raceway latch releases,
raceway swings free.
c
Secure the raceway in place by
lifting until the locking latch engages.
d
Push the tab on the locking latch to the left
to release.
Press raceway down and back until an audible click
indicates that it is latched in position.
Replace heater front panel.
6.2

Main Wiring Connections

The main wiring connections should be available
externally to the heater at the time it is unpacked. Use
fl exible conduit to run the main power lines from the
power source to the heater connections. No external
junction box is required.
Connect Conduit at Port
in Side Panel
c
a
|
Gas-Fired Pool & Spa Heater
and the
Connect Power Source
to Heater Leads
b
Heater Interior
(access from front panel)
Installation & Operation Manual
b
NOTE: Before the raceway can be rotated for the fi rst time a
shipping zip tie must be cut. This zip tie is threaded at the raceway
release point see item (a). While cutting this zip tie be sure not to
damage or abrade any of the wires.
Ensure that all electrical power is shut off to the
heater at the breaker.
Ensure that the fi lter pump is off and will stay off for
the remainder of the procedure.
Follow applicable service access instructions from
Section
6.1.
a
Run conduit and power lines from main power
source to the heater side panel.
d
b
Make wire connections via wire nuts.
c
Push wire connections through the knockout into
the heater body. Be careful not to damage or abrade any
wiring during this procedure.
d
Secure the conduit to the heater body panel at the
knockout using a suitable conduit connector or elbow.
NOTE: If the heater is converted to accept 120V, the "Hot" wire
of the 120V power supply has to be connected to the black wire
(ACH1) on the power distribution board and the "Neutral" wire of the
120V power supply has to be connected to the red wire (ACN1) of
the power distribution board.Please see
Page 25
ENGLISH
c
a
Figure 12
for details.
d