Connecting To A Remote Pool-Off-Spa Selector (3-Wire Connection); Configure The Control Panel; Connecting To An Aqualink® Control System Or Remote Tstat (2-Wire Connection); Install The Remote Tstat - Jandy JXi 200 Installation And Operation Manual

Jandy pro series gas-fired pool and spa heater
Table of Contents

Advertisement

Jandy
Pro Series, JXi
®
7.1

Connecting to a Remote Pool-Off-Spa Selector (3-Wire Connection)

Turn off the power to both the pool/spa control
system and the heater unit.
Follow applicable service access instructions from
Section
6.1.
Run the wires from the pool/spa control system
through the low voltage knockout on the right or left
hand side of the heater.

Configure the Control Panel:

7.1.1
Make sure the pool heater is OFF.
Press and hold MENU, then the POOL and SPA
buttons for 5 seconds to access Service Setup mode.
NOTE: The display will revert back to OFF after 1 minute since the
last key press.
Press Up or Down to display REMOTE.
7.2
Connecting to an AquaLink® Control System or Remote TSTAT (2-Wire Connection)
An interrupt (on/off-type) remote can be connected as
a Remote TSTAT to turn the heater on or off but not
perform any other function. When using this type of
7.2.1

Install the Remote TSTAT:

Turn off the power to both the pool/spa control
system and the heater unit.
Follow applicable service access instructions from
Section
6.1.
Run the wires from the pool/spa control system
through the low voltage knockout on the right or left
hand side of the heater.
Connect the wiring from the pool/spa control system
to the heater remote control terminal.
Connect the two wires to Pool and Common (not
Spa) on the J6 terminal bar. See
Reinstall panel.
Restore power to the heater and the pool/spa control
system.
Configure the Control Panel:
7.2.2
Make sure the pool heater is OFF.
Press and hold MENU, then the POOL and SPA
buttons for 5 seconds to access Service Setup mode.
NOTE: The display will revert back to OFF after 1 minute since the
last key press.
Press MENU, REMOTE OFF (default remote) is
displayed.
|
Gas-Fired Pool & Spa Heater
item "b".
Figure 12
Installation & Operation Manual
Connect the wiring from the pool/spa control system
to the heater remote control terminal. See
item "b".
Connect the three wires to Spa, Pool & Common
terminals of the J6 terminal bar.
Reinstall front panel.
Restore power to the heater and the pool/spa control
system.
Press MENU, REMOTE OFF (default remote) is
displayed.
Use Up or Down to scroll through the Remote options
until HI-LO-COM is displayed, then press MENU to
select.
Press POOL or SPA to exit Service Setup mode.
connection, remember to set the heater control to "pool"
or "SPA" and set the thermostat control to maximum.
NOTE: If you install a time clock to control the filter pump
operation, it is recommended that the time clock have its own low
voltage (Fireman's) switch to turn off the heater before turning off
the pump. The switch should shut off the heater about 15 minutes
before the filter pump shuts off. This will allow for a more efficient
operation by removing any residual heat contained in the heat
exchanger back to the pool.
To avoid damage to the heater, do not connect the power supply
of the heater to the output side of the clock if your time clock
simply interrupts the high voltage power supply or has a high voltage
output. Doing so will prevent the blower from purging the residual
heat from the heater when the heater turns off. The blower must be
allowed to run for 45 seconds after the heater shuts off.
Use Up or Down to scroll through the Remote options
until REMOTE TSTAT is displayed, then press MENU to
select.
Press POOL or SPA to exit Service Setup mode.
Press POOL or SPA to adjust the set point to the
maximum 104°F (40°C).
ENGLISH
CAUTION
Page 27
Figure 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jxi 260Jxi 400

Table of Contents