Indoor And Outdoor Shelter Exhaust Conversion - Jandy JXi 200 Installation And Operation Manual

Jandy pro series gas-fired pool and spa heater
Table of Contents

Advertisement

Jandy
Pro Series, JXi
®
3.3.3

Indoor and Outdoor Shelter Exhaust Conversion

For both Category I and Category III vent types the
heater must fi rst be converted to indoor exhaust type. In
order to complete the conversion you will need to order
exhaust conversion R-Kit R0711900.
a
Remove two screws securing the exhaust grill to the
exhaust grill backplate.
b
Remove exhaust grill.
c
Remove the two screws securing the rain shield to
the exhaust backplate.
d
Remove Rain Shield.
e
Remove the remaining two screws securing
the exhaust backplate to the exhaust outlet.
f
Remove the exhaust grill backplate.
g
Using two #10 thread cutting screws secure
the vent adapter from R-Kit R0711900 to the
exhaust outlet.
h
If venting for Category I, install an
appropriate vent pipe increaser to accommodate
the correct pipe size from
vent adapter using the screw clamp.
When the installation requires horizontal venting
in excess of what is allowed for Category I
installations or calls for horizontal discharge, the
JXi may be installed with a Category III venting
system.
Vent the heater either vertically
or horizontally using Al29-4C
stainless steel components. Consult
manufacturers such as Z-Flex
or Heat Fab
®
to obtain approved
components. Venting materials
1738 for
®
must comply with UL
Category III, Special Gas Vent. In
Canada, the venting materials must
be ULC S636 compliant.
i
If venting for Category III,
install appropriate vent pipe
from
Table 1.
Secure to the vent
adapter using the screw clamp to
ensure a proper seal.
Double check that there are no possible leak paths
between joints. If a leak path is identifi ed or suspected
it can be sealed using red RTV 600° F rated silicone
adhesive.
In the Commonwealth of Massachusetts, additional requirements, covered in document CMR 248 5.00, which supersede some of the require-
ments of ANSI Z223.1 (NFPA 54) apply to Side Wall Horizontally Vented appliances. If installing this product using an approved side-wall hori-
zontal vent system in the Commonwealth of Massachusetts, be sure to adhere to these additional requirements. These requirements include
verbiage that says that the property owner is to ensure that Carbon Monoxide Detectors are installed in the vicinity of the appliance and also on
all levels of the dwelling in which the appliance is installed.
For further instructions, contact Technical Support at 800.822.7933.
|
Gas-Fired Pool & Spa Heater
Table 1.
Secure to the
®
4" Vent Pipe
IMPORTANT NOTE
Installation & Operation Manual
a
Exhaust Outlet
Exhaust Grill Backplate
Rain Shield
c
e
b
Exhaust Grill
Exhaust Outlet
Vent Elbow
Vent Adapter
Increaser
h
y I
t e g o r
f o r C a
O R
i
I I I
t e g o r y
f o r C a
When using parts or materials from other manufacturers
please be sure to follow the manufacturers instructions
completely to ensure harmonious function.