Page 26
Figure 19. Heater drain locations.
Figure 20. Pressure switch copper tubing.
4.
Turn on the main gas supply valve to the heater,
outside the heater jacket.
5.
Turn on the heater following the lighting instruc-
tions found on the inside of the heater, or page 17
of this manual.

8.3 Inspection and Service

The Lite2 LD heater is designed and constructed
to provide long performance life when installed and
operated properly under normal conditions. Periodic
inspections, especially at spring start-up, are important
to keep your heater running safely and efficiently
through the years. Improper maintenance can result in
conditions where nausea or asphyxiation from carbon
monoxide or flue gases could cause severe injury,
property damage or death.
WARNING
Improper installation or maintenance can cause
nausea or asphyxiation from carbon monoxide in flue
gases which could result in severe injury, or death.
AVERTISSEMENT
Une installation ou un entretien inadéquat peut
causer la nausée ou l'asphyxie en raison du
monoxyde de carbone présent dans les gaz de
combustion et même entraîner des blessures graves
ou la mort.
8.3.1 Owner Inspection
Jandy Pool Products, Inc. recommends that you
inspect the heater on a continual basis and especially
after abnormal weather conditions. The following basic
guidelines are suggested for your inspection:
1.
Keep the top and surrounding area of the heater
clear of all debris.
2.
Keep the area around and beneath the heater
clean and free of all combustible materials such
as paper, leaves, etc.
3.
Do not store or use gasoline or other flammable
vapors, liquids or chemicals in the vicinity of this
or any other appliance.
Ne pas entreposer ni utiliser d'essence ni d'autres
vapeurs ou liquides inflammables à proximité de
cet appareil ou de tout autre appareil.
4.
Do not use the heater if any part has been under
water. Immediately call a qualified professional
technician to inspect the heater and replace any
part of the control system which has been
submerged.
N'utilisez pas cet appareil s'il a été plongé dans
l'eau, même partiellement. Faites inspecter
l'appareil par un technicien qualifié et remplacez
toute partie du système de contrôle et toute
commande qui ont été plongés dans l'eau.
5.
If the heater is equipped with a pressure relief
valve, check for corrosion in and around the
valve. With the filter pump on, lift the release
lever on the top of the valve to make sure that

Hide quick links: