Data Configuration; Application's Logical Element; Functions - Teltonika TWCT22 User Manual

Alarm monitoring & control system
Hide thumbs Also See for TWCT22:
Table of Contents

Advertisement

8 DATA CONFIGURATION

Data configuration is executed by the internal WEB server application. You need to connect TWCT22
to PC and the server program should be run.

8.1 APPLICATION'S LOGICAL ELEMENT

System log
4 IN
2 AIN
Figure 8.1.1

8.2 FUNCTIONS

TWCT22 is a monitoring and control device for remote objects. Remote commands are described by
three definitions: logic (the relationship between elements), event (an occurrence detected by the device)
and action (a state or process that is controlled by the device). Events are following occurrences: four
digital inputs, two analog inputs, two types of receiving messages (SMS, call). Actions are those possible
processes: relay state controlling (on, off, toggle) and sending message (SMS, email, call).
User is authorized person which is allowed to use the device via messages. Users can be jointed into the
group.
The device is configurable through internal WEB server interface via GSM network and RS232 interface.
System log is the register of the device's status important occurrences.
Events
WEB server
RS232
Actions
Logics
Users,
users groups
GSM connection
RELAY
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents