4 | Key to symbols and safety instructions
Ensuring the appliance performs to the specifications
stated on the rating label.
Demonstrating the operation of the appliance to the
customer before leaving.
Handing the operating instructions to the customer.
THIS APPLIANCE IS NOT SUITABLE FOR POOL OR SPA POOL
APPLICATIONS.
NOT SUITABLE FOR COMMERCIAL BOOSTING OF A WARM
WATER RECIRCULATION SYSTEM
Regulations
All local by-laws and regulations pertaining to installation and
use of gas appliances must be observed.
This appliance must be installed in accordance with the
manufacturers installation instructions, AS/NZS5601, AS/
NZS3500, and all Local Building & Gas fitting regulations.
The appliance must not be installed outdoors. The appliance is
approved for indoor installation only. Do not install this
appliance with any modification or alteration.
Failure to install this appliance in accordance with these
installation instructions will void the warranty and may create
an unsafe situation.
Installation
DANGER: Explosion Risk!
▶ Always turn off the gas valve before
carrying out any work on components
which carry gas.
DANGER: Appliance malfunction!
This appliance must be installed with no
obstructions to the flue terminal.
▶ Periodic checking of the flue terminal to
ensure no blockage or obstruction of the
openings from plants, debris or insects
must be carried out.
The installation of gas, water, and electrical
supply, and the initial startup are to be
performed by an authorised person.
Not suitable for pool or spa pool applications.
Not suitable for commercial boosting of
warm water recirculation systems.
6 720 810 560 (2016/06)
All gas appliances require adequate air intake
to ensure correct combustion. Insects and
dirt ingress may affect combustion causing
sooting. If you notice sooting from the flue
outlet the unit would require servicing. Pest
and dirt ingress is not covered by the
manufacturers warranty.
Important information
▶ Determine the most appropriate location for the appliance.
Install as close as possible to the most frequently used hot
water outlet.
▶ Ensure the mounting structure is capable of supporting the
weight of the appliance once installed. Secure the heater to
the wall using fixings suitable for the weight of the
appliance and the wall material.
▶ Install gas and water isolation valves as close as possible to
the appliance. Only use a gate valve or full flow ball valve
(fixed mechanism type) for cold water.
▶ Check the cold water supply pressure to ensure it meets
the required supply pressure for the appliance. (see
table 5, page 9).
▶ If inlet water pressure exceeds 800 kPa a pressure limiting
valve (500 kPa) MUST be fitted. The preferable location for
the pressure limiting valve is at the water meter.
▶ Where the pressure limiting valve is less than 3 metres from
the hot water unit, it must be fitted in conjunction with a
cold water expansion valve (700 kPa), between the water
heater and the pressure limiting valve.
▶ Failure to comply with this requirement may void the
warranty.
▶ Refer to AS/NZS5601 for the relevant gas pipe sizing.
▶ After finishing the gas piping system, the pipes must be
thoroughly purged and leak tested. This test must be
performed with the gas isolation valve of the appliance
closed.
▶ Ensure the gas pressure and flow through the regulator are
appropriate for the consumption of the heater (see table 5,
page 9). Refer to AS/NZS5601 and AS3500, for the
relevant pipe size.
Note: Incorrect pipe sizing or gas supply pressure may cause
the appliance to under perform. Service calls for incorrect pipe
sizing and/or gas pressure, will NOT be covered under
warranty.