Bosch Optiflow Professional GWH12 Installation Manual page 11

Room sealed gas continuous flow water heaters 1 ctd e23/31 f5 l
Hide thumbs Also See for Optiflow Professional GWH12:
Table of Contents

Advertisement

Type
Description
---
Flue Elbow Ø 60/100 90°
---
Flue Elbow Ø 60/100 45°
---
Flue Terminal Extension DN60/100 350mm
---
Flue Terminal Extension DN60/100 750 mm
---
Flue Terminal Extension DN60/100 1500 mm
---
Horizontal Condensate Trap Ø 60/100
---
Vertical Flue Condensate Trap Ø 60/100
Table 6
Flue gas accessories Ø60/100 mm
Add note on using 100m 2 pce clips.
Flue condensate collector
We advise using a condensate trap when the flue length and the
lowest average inlet air temperature is likely to result in
condensate forming during operation.
When the intersection of the flue length and lowest average
inlet air temperature is in the white section of the graph, a
condensate trap is required. (See Fig. 4)
Optiflow Professional
Reference
7 736 995 079
7 736 995 071
7 736 995 059
7 736 995 063
7 736 995 067
7 736 995 087
7 736 995 089
10 m
9 m
8 m
7 m
6 m
(A)
5 m
4 m
3 m
2 m
1 m
0 m
-10°C
-5°C
Fig. 4
[A] Flue pipe length
[B] Lowest average inlet air temperature
Bosch 4000S flue components
All 4000S coaxial flue components have an internal pipe
diameter of 60 mm and an external pipe diameter of 100 mm.
Product details | 11
0°C
5°C
10°C
15°C
(B)
6 720 810 560 (2016/06)
20°C
25°C
6720809968-04.3V

Hide quick links:

Advertisement

Table of Contents
loading