MATE SCREENS

SELL MENU

The SELL section is used to set the functions that control the process of selling power back to the utility grid. This menu is only
operational for Grid-Tie FX's and is not operational with "Export" FX's at this time. These functions include setting the voltage at which
the FX sells back to the utility grid, setting the window in which the Grid-Tie function operates, and to enable or disable the Grid-Tie
function. The default values enable the Grid-Tie FX to sell back to the utility grid after the FX has completed a charge cycle. To
disable this charge cycle, press the <AC IN> "hot" button four times, press <BULK> , press <STOP> and then press <OK> . The FX
waits 5 minutes after it has accepted the utility grid as an AC source and must be above the "sell RE volts" (found in this menu) to start
selling.
ADV/FX/PAGE1--------
choose category:
ADV
INV
CHGR
PG2
ADV/FX/PAGE2--------
choose category:
PG1
GRID
GEN
PG3
ADV/FX/PAGE3--------
choose category:
PG2
AUX
STACK
PG4
ADV/FX/PAGE4--------
choose category:
PG3
SELL
CAL
MAIN
ADV/FX/SELL------P00
sell re
12.8vdc
volts
DOWN
INC
DEC
PORT
ADV/FX/SELL------P00
grid tie
IEEE
window
DOWN
IEEE USER PORT
ADV/FX/SELL------P00
grid tie
GridTie
authority
DOWN
INC
DEC
PORT
ADV/FX/SELL------
selling setup
completed
TOP
ADV
MAIN
Installation & Programming Manual
Page 54
Once the password has been correctly entered, the ADV - CHOOSE CATEGORY: screen is
displayed. Selecting <PG2> shows a second screen of categories.
Selecting <PG3> shows a third screen of categories.
Selecting <PG4> shows a fourth screen of categories.
Selecting <SELL> allows adjustment of the Grid-tie and selling set points and operation.
The SELL RE VOLTS (RE = Renewable Energy) screen allows the user to set the voltage at
which they would like to sell battery power back to the utility grid. If the battery voltage is above
the voltage shown on this screen and the FX isn't charging then the FX will sell power back to
the utility grid. This setting has a range between 10.0 vdc and 15.0 vdc in 0.1vdc increments.
The GRID TIE WINDOW screen controls the voltage and frequency windows that the grid-tie
function operates in. If the FX repeatedly disconnects from the utility grid this value may need to
be changed. This function should not , I repeat, should not be changed without consulting
OutBack Power Systems first.
The GRID TIE AUTHORITY screen allows the user to turn on or off the selling function of the FX.
When the screen displays "GridTie" (default), the FX will sell power under the correct conditions.
Pressing DEC will change "GridTie" to "No Sell" and the selling function will be disabled.
Pressing INC will change the display back from "No Sell" to "GridTie".
Selecting TOP returns the user to the top of the ADV/FX/SELL menu section. Selecting ADV
returns you to the advanced screen to allow selection of another product connected to the MATE.
Selecting MAIN returns the display to the MAIN screen.
FX & VFX "E" Series Inverter/Charger System
900-0027-2
Rev 7.1
Copyright 2003
06/08/06
OutBack Power Systems, Inc.
nd
19009 62
Ave NE, Arlington WA 98223 USA
Tel 360 435 6030
Fax 360 435 6019

Hide quick links: