Troubleshooting
Problem
With gas operation:
The refrigerator does
not work.
RM5385 only:
In automatic mode:
The refrigerator is
being operated with
gas although it is
connected to the
AC mains.
The refrigerator does
not cool sufficiently.
26
Possible cause
The gas cylinder is empty.
The gas valve is closed.
Air is in the supply line.
The mains voltage is too
low.
The ventilation around
the cooling unit is not
sufficient.
The evaporator is iced up.
The temperature is set too
high.
The ambient temperature
is too high.
Too much food at once
was placed in the
refrigerator.
Too much warm food at
once was placed in the
refrigerator.
The refrigerator has not
been operating for very
long.
RM5310 – RM5385
Suggested remedy
Replace the gas cylinder.
Twist the valve open.
Switch the refrigerator off
and on again. Repeat the
procedure three or four times
if necessary.
The refrigerator changes to
AC power supply automatically
as soon as the mains voltage is
sufficient again.
Check that the ventilation grille
is not obstructed.
Check whether the refrigerator
door is properly closed. Defrost
the refrigerator.
Set a lower temperature.
Remove the ventilation grille
for a while so that warm air can
escape quicker.
Remove an item.
Remove the warm food and
leave it to cool down before
putting it in again.
Check the temperature again
after four or five hours.
EN