If an emergency alarm is initiated by mistake:
1.
Press
.
2.
Enter user access code.
3.
Press OK from the Alarm Restored screen.
4.
Press CLOSE from the Alarms and Faults screen to return to the Main screen.
Note: An aborted alarm will result in audible and visual annunciation.
Note: The alarm screen image above is for a panic alarm. The alarm could be a fire or police alarm.
Arming and disarming
Use the steps below to arm and disarm the system:
To disarm:
1.
Press
.
2.
Enter the code when the keypad screen appears. If an incorrect code is entered, press CLEAR and enter the correct code.
To Arm Stay, Arm Night, or Arm Away:
See Table 1 on page 2 for more information.
1.
Press
.
2.
Set arming options. To display arming options, press SHOW OPTIONS. To
hide arming options, press HIDE OPTIONS.
3.
Press ARM STAY, ARM NIGHT, or ARM AWAY.
Note: If no trouble conditions exist, proceed to step 6.
5.
From the Arm Protest screen, press BYPASS next to any devices that need
to be bypassed.
6.
The arming countdown screen will appear. To cancel arming, press CANCEL
in the top right corner of the countdown screen.
Note: Entry and exit delay beeps sound once a second until the last 10 seconds
when the beeps sound twice a second.
Exit/entry delay
AdvisorOne provides a delay after entering or exiting the premises before the system is armed or disarmed. An exit time restart
feature will recognize when the system is armed, a person leaves the premises and quickly reenters The system will restart the exit
delay to give users the full exit delay again. The restart will only occur once.
Double knock
Double knock (two-trip) refers to a zone needing two sensor trips (one or multiple sensors) to be present to generate an alarm. If
the zone becomes active and would normally trigger an alarm, either the zone needs to remain active for the programmed Double
Knock time or the zone has to return to normal and trigger again within the Double Knock interval before sending an alarm to the
central station.
Fire alarm verification
If this option is off, the panel immediately reports to the central station when a smoke detector goes into alarm.
With this option on, if a single smoke detector goes into alarm, the panel will not report for 60 seconds unless another smoke
detector goes into alarm. If the first smoke detector is cleared of an alarm within the first 60 seconds, no report will be sent to the
central station unless it or a second smoke detector goes into alarm within the panel siren timeout period (5 minutes). Contact the
dealer for more information.
AdvisorOne Quick Operation Guide
Exit delay - Turn this option ON to enable the
exit delay.
Silent exit. Turn this option ON to silence the
exit beeps during arming.