DO NOT advance the throttle before start-up.
Advancing the throttle overrides the electronic
idle control system.
If the outboard is started with the throttle ad-
vanced, the outboard will be in a safety mode.
It will not respond to throttle until the throttle is
returned to slowest IDLE position
After the engine starts, the engine manage-
ment module (EMM) automatically increases
idle speed slightly. Idle speed will decrease as
the engine warms up.
Engine Starting
Turn the key switch fully clockwise to the
START position.
NOTICE
The starter motor can be dam-
aged if operated continuously for more
than 20 seconds.
Upon start-up, release the key.
If the engine did not start, release the key mo-
mentarily, then try again.
Each time the key switch is turned from OFF
to ON, the warning system will self-test. Refer
to Engine Monitoring on page 35. If the
warning system fails to self-test during start-
up, see your Dealer.
If your outboard does not react normally to
this starting procedure or if it fails to start, re-
fer to Troubleshooting on page 54.
After Engine Starts
Check the water pump indicator. A steady
stream of water indicates the water pump is
working. If a steady stream of water from the
water pump indicator is not visible, stop the
engine. Refer to Engine Overheating on
page 37.
1. Water pump indicator
Engine Stopping
Move control handle to NEUTRAL.
Turn key switch counterclockwise to the OFF
position.
1
Key
007015
1. Key switch, OFF position
Remove the key when the boat will be unat-
tended.