SECTION 9 − OPERATING AUXILIARY EQUIPMENT

9-1. Generator Power Receptacles And Supplementary Protectors

!
Use GFCI protection when operat-
ing auxiliary equipment. If unit does
not have GFCI receptacles, use
GFCI-protected extension cord.
!
Unplug power cord before attempt-
ing to service accessories or tools.
.
Generator power decreases as weld
current or air compressor output in-
creases.
1
120/240 V 50 A AC Receptacle RC1
2
120 V 20 A AC Receptacles RC2
and RC3 (GFCI Receptacles Shown)
RC1 supplies 60 Hz single-phase power at
weld/power speed. Maximum output is
11.0 kVA/kW.
RC2 and RC3 supply 60 Hz single-phase
power at weld/power speed. Maximum out-

9-2. Simultaneous Weld And Power

.
This table shows simultaneous weld and power output with air compressor off.
Weld Current in Amperes
300
250
200
150
100
0
1
4
put from RC2 or RC3 is 2.4 kVA/kW.
GFCI Receptacles
If a ground fault is detected, the GFCI Re-
set button pops out, red light turns on, and
the circuit opens to disconnect the faulty
equipment. Check for damaged tools,
cords, plugs, etc. connected to the recep-
tacle. Press button to reset receptacle and
resume operation.
.
At least once a month, run engine at
weld/power speed and press Test but-
ton to verify GFCI is working properly.
!
If GFCI red light blinks continu-
ously, replace receptacle.
3
Supplementary Protector CB1
CB1 protects receptacles RC1, RC2, and
RC3 from overload. If CB1 opens, the re-
Total Power in Watts
1000
3500
5200
6700
8000
11,000
.
A complete Parts List is available at www.MillerWelds.com
5
6
2
ceptacles do not work. Place switch in On
position to reset.
4
Supplementary Protector CB2
5
Supplementary Protector CB3
CB2 protects RC2 and CB3 protects RC3
from overload. If a supplementary protector
opens, the receptacle does not work.
.
Press button to reset supplementary
protector. If supplementary protector
continues to open, contact Factory
Authorized Service Agent.
Combined output of all receptacles limited
to 10 kVA/kW rating of the generator.
EXAMPLE: If 20 A is drawn from each 120
V duplex receptacle, only 20 A is available
at the 240 V receptacle:
2 x (120 V x 20 A) + (240 V x 25 A) = 9.6
kVA/kW
120 V Receptacle Amperes
10
31
46
60
70
88
3
Ref. 245 069
240 V Receptacle Amperes
5
15
23
30
35
44
OM-229 930 Page 43