Use

The hood has been designed to be installed
and used either as a "Exhausted model", or
as a "Recirculation model".
Exhausted model (see symbol
installation booklet)
Cooking steam is sucked and channelled
outside the house through a discharge duct
(not supplied), fitted to the hood steam
outlet.
Ensure that the discharge duct is correctly
fitted to the air outlet, unit using an
appropriate connection system.
Important: If already installed, remove the
charcoal filter/s.
Where fixing or mounting screws or other
fixing devices are used, that penetrates into
the range hood with a accessible metallic
enclosure or class II construction, to attach
an accessory, the instructions shall indicate
the required location of these screws or
fixing devices and include the substance of
the following warning.
Failure to install the screws or fixing device
in accordance with these instructions may
results in electrical hazard.
Recirculation model (see symbol
installation booklet)
The air is filtered through one or more the
charcoal filters, and then resent into room.
Important: Ensure appropriate air
in
circulation around the hood.
Important: If the hood is supplied without
charcoal filters, these must be fitted before
the hood can be used. Filters are available
in shops.
The hood should be installed away from
particularly dirty areas, windows, doors and
heat sources.
The accessories for wall fixing are not
included because walls made of different
materials require different types of fixing
accessories. Use fixing systems suitable for
the walls of your home and the weight of
the appliance. For more details, contact a
specialized dealer.
Keep this booklet for future consultation.