OPTIONAL ACCESSORIES

Optional Accessories
Guardian™ Ultraviolet Monitor - Analog/Digital
Sentry™ Safety Sensor
Steralert™
Audio Alarm
Elapsed Time Indicator Universal Input
Wall Mounting Kit
Time Delay Mechanism
Quantum Thermal Optimizer:
Solenoid Valve - Brass
Sure Flo™ Flow Control Valve

MAINTENANCE

The water purifi er is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed
maximum concentration levels, see "Water Quality" in the "Product Application" section. Ordinary maintenance consists of;
Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service.
Cleaning of the quartz sleeve, when conditions warrant. It is recommended that the inspection of quartz sleeve be performed
after one month of use. If quartz sleeve is found to be coated (not clear), then frequency of cleaning must be done more often.
Deposits or discoloration on the surface of quartz sleeve are caused by excessive levels of the subject contaminant within
the water that is in contact with the quartz sleeve. Most often false deposits on the quartz sleeve are caused by an excess of
calcium (hardness), iron or manganese. Table 1 on Page 4 lists the maximum recommended concentration of these minerals
in the water that passes through the ultraviolet purifi er. If you encounter diffi culty due to deposits on the quartz sleeve, your
dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant. If quartz sleeve is
clean (clear) then frequency of cleaning may be extended. NOTE: SANITRON
with a manual wiping mechanism making the process of routine cleaning easier and therefore, recommended weekly
or at the very least monthly to insure your performance. NOTE: The use of optional Guardian™ Ultraviolet Monitor
will detect loss of transmission due to coating on the quartz sleeve.
Always disconnect the water supply and completely drain the water purifi er if it will be subjected to temperatures below
freezing.
Contact factory with questions.
I
NSPECTION
1.
Regularly inspect the water purifi er to ensure that the germicidal lamp is still in operation.
On purifi ers not equipped with the Ultraviolet Monitor, lamp operation can be verifi ed by a visible glow through the
translucent sight port. This provides an indication of lamp operation and does not indicate the level of ultraviolet
intensity or transmission through the water.
On purifi ers so equipped, the Guardian™ Ultraviolet Monitor provides visual indication of the ultraviolet intensity
through the quartz sleeve and water in the purifi er chamber.
2.
To ensure proper operation of the water purifi er, regular biological testing should be performed on a schedule recommended
by local public health authorities, or at minimum; at installation, quarterly for the fi rst year of service and annually, at lamp
replacement, for the life of the water purifi er.
3.
Additional testing should be performed whenever modifi cations, change, or additions are made to plumbing system, pumps,
well source water etc. to ensure adequate disinfection under new condition.
8
Table 3 - Optional Accessories
Available For:
S17A through S50C
S17A through S50C
S17A through S50C
S17A through S50C
S17A through S50C
S17A through S50C
S17A through S50C
S17A through S50C
S17A (3/4")
S23A (3/4")
S37C (1")
S50C (1-1/2")
S17A (3/4")
S23A (3/4")
S37C (1")
S50C (1-1/2")
Most optional accessories are
available for operation at 120v 60Hz
or 220v 50Hz. Please specify.
Consult Factory for 12v DC or other
special input power requirements.
 Unless otherwise specifi ed PVC
fl ow control valves are supplied.
All PVC and Stainless Steel fl ow
control valves are male NPT.
Consult Factory for other fl ow
control valves
®