Installation - Sanitron S17A Owner's Manual

U ltraviolet water purifiers
Table of Contents

Advertisement

I
NSTALLATION
1.
Remove water purifi er from shipping carton. Inspect water purifi er, power cord and plug for damage. Do not operate if there
is any damage to the purifi er, power cord or plug. Models S17A and S23A are shipped with the lamp already installed, while
the lamp in the S37C and the S50C is packed separately. Keep the lamp aside for installation once the purifi er has been
properly installed.
2.
Units occasionally experience damage in shipment due to the fragility of the quartz sleeve. It is, therefore, recommended
to inspect the water purifi er for damage to the quartz sleeve after it has been removed from the shipping carton. Each end
of the unit as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the quartz
sleeve shows signs of damage it should be replaced before the purifi er is pressurized. See "Quartz Sleeve Cleaning or
Replacement" in the "Maintenance" section for the proper method of replacing the quartz sleeve in your water purifi er.
Note:
Solenoid plugs into the top of the Time Delay,
and the Time Delay into the Ultraviolet Monitor
Incoming
COMMON
Water
PRE-TREATMENT or
Supply
PUMPING DEVICES
1. Deionizer
2. Water Softener
3. Carton Filters (GAC)
4. Pressure Tank
5. Pump
6. Reverse Osmosis
7. Prefilters
Ultraviolet Water Purifiers
should be installed closest
to the point of use. (POU)
Note: Drain Pan
Recommended. Water
Purifier should be
installed at minimum
of 18" above floor.
3.
The water purifi er should be mounted horizontally on a fl at dry surface. Secure the water purifi er using the mounting holes
in the ballast housing or with the optional wall mounting kit. The purifi er should not be solely supported by its plumbing
connections.
4.
The water purifi er must be connected to the cold water line only.
5.
Installation requires that a 5-micron sediment fi lter or fi ner be installed, in line, prior to the water purifi er. The sediment fi lter
will stop or trap large particulates from entering the water purifi er. Particulates may cause damage to the quartz sleeve, as
well as interfere with the purifi er's ability to disinfect the water. The sediment fi lter may also help to reduce the amount of
routine cleaning of the quartz sleeve.
6.
Shut off valves should be installed on both the inlet and outlet sides of the water purifi er. The use of bypass valves is not
recommended. The shut off valves allow the purifi er to be isolated from the water supply, which is required when removing
the quartz sleeve.
7.
Unions should be installed on both the inlet and outlet of the water purifi er; this will allow easy removal of the water purifi er
from the plumbing, if required. Apply Tefl on® tape to threads of inlet and outlet ports to ensure a tight seal.
8. When all plumbing connections are complete, allow water to enter the water purifi er at a low fl ow rate, until the purifi er is
full. NOTE: Close the purifi er outlet valve to pressurize the chamber. With the purifi er pressurized, it should be checked
for leaks. Once it is determined that there are no leaks, the inlet valve can be fully opened.
9.
For Models with lamps packed separately, install lamp following the steps in "Lamp Installation or Replacement" section.
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling.
10.
Plug water purifi er into approved ground fault circuit interrupt (GFCI) receptacle. Confi rm lamp operation indication at
sight port. (Continued on Page 7)
6
Figure 2 - Recommended Installation
Cold Water Line
5 Micron Filter
Manual Wiper
"X"
Recommended Minimum Clearance
For Lamp or Quartz Sleeve Removal
(avoids ultraviolet degradation of exposed plastic pipe)
OPTIONAL EQUIPMENT
Two Minute Time Delay
Solenoid Valve
Flow Control Valve
Elbow
OPTIONAL EQUIPMENT
Ultraviolet Monitor
Audio Alarm
Valve
Union
OPTIONAL EQUIPMENT
Wall Mounting Kit
Use of Metal Pipe is recommended for 12"
past elbow to the inlet or from the outlet.
Elbow
POINT OF USE (POU)
Ultraviolet Water Purifiers
should be installed closest
to the point of use.
Outlet Line to point of use
to be as short as possible
Valve
Union
6" Minimum
Clearance for
Gland Access
Ultraviolet Water Purifier