INSTALLATION

L
OCATION
1.
The water purifi er is intended for indoor use only. The water purifi er is designed to mount horizontally. The water purifi er
should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area
surrounding the water purifi er, should be between 35
2.
Electrical power supplied to the water purifi er MUST match power requirements listed on the water purifi er. Use of a voltage
surge protector is recommended.
3.
Plug water purifi er only into an approved ground fault circuit interrupt (GFCI) receptacle.
4. The water purifi er should be located in a dry, well-lit area, which provides enough room to perform routine maintenance. This
includes a minimum distance of one chamber length from the wiper end, to allow for cleaning and/or the changing of the
lamp and quartz sleeve as well as a minimum of 6" on the opposite end of the water purifi er. Minimum clearance to fl oor 18''.
5. The water purifi er should always be located closest to the point of use. This reduces the chance of the purifi ed water being
re-contaminated by bacteria in the water distribution system after the water purifi er.
6.
CAUTION: As with any water handling device, the water purifi er should be located in an area where any possible
condensation or leakage from the water purifi er, any purifi er accessory and/or plumbing will not result in damage to the
area surrounding the water purifi er. For added protection, it is recommended that a suitable drain pan be installed under the
purifi er. The drain pan must be plumbed to an adequate, free fl owing drain to prevent water damage in event of a leak. There
are numerous leak detection/fl ood stop devices, available on the market today, designed to stop fl ow of water, reducing the
chance of water damage due to leakage. For more details regarding leak prevention and/or limiting damages due to leaks
please contact factory.
7.
The water purifi er should be located after all other water devices, such as De-ionizers, Water Softeners, Carbon Filters, Pre-
Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the purifi ed water being re-contaminated by
bacteria in any of these units.
D
D
IMENSIONAL
ATA
Model
A
S17A
8-3/4"
S23A
14-3/4"
S37C
28-1/2"
S50C
40-7/8"
All specifi cations, dimensional data, etc are approximate and subject to change without notice.
Figure 1 - SANITRON
Table 2 - SANITRON
B
C
D
17"
8-3/4"
10"
23"
13-1/4"
14-1/2"
37"
16"
18"
50"
26"
30"
o
o
F and 100
F.
®
Dimensional Drawing
®

Dimensional Data

E
F
G
17-3/8"
3-5/8"
4-5/16"
23-3/8"
3-5/8"
4-5/16"
37-3/8"
4-15/16"
5-11/16"
50-3/8"
4-15/16"
5-11/16"
H
J
Inlet/Outlet
8-3/16"
7-3/16"
3/4"m NPT
8-3/16"
10-3/16"
3/4"m NPT
9-1/2"
11-1/8"
1"m NPT
9-1/2"
13-13/16"
1- 1/2"m NPT