Sanitron S17A Owner's Manual

U ltraviolet water purifiers

Advertisement

U LT R AV I O L E T WAT E R P U R I F I E R S
Models S17A, S23A, S37C & S50C
Read and Follow All Safety Instructions. Save These Instructions
SINCE 1963
Manufacturers / Engineers / Sales / Service
Germicidal Ultraviolet - Equipment & Lamps
Extensive Product Information Available at:
ultraviolet.com
Document No. 98-1377B9 • August 2014 • ©2014 Atlantic Ultraviolet Corporation®
Installation
Installation,
Operation
& Maintenance
®
1

Advertisement

Table of Contents
loading

Summary of Contents for Sanitron S17A

  • Page 1 ® U LT R AV I O L E T WAT E R P U R I F I E R S Models S17A, S23A, S37C & S50C Read and Follow All Safety Instructions. Save These Instructions Installation, Installation Operation &...
  • Page 2: Table Of Contents

    ® line of water purifi ers, Models S17A, S23A, S37C and S50C. Questions that are not specifi cally answerable by these instructions should be directed to the Factory. Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage. Carefully inspect and report all damages.
  • Page 3: Safety Warnings

    SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
  • Page 4: Product Application

    No tools are required. RINCIPLE OF PERATION The SANITRON ® design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to ultraviolet disinfection, is a function of time and the intensity of ultraviolet radiation to which the water is exposed.
  • Page 5: Installation

    Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the purifi ed water being re-contaminated by bacteria in any of these units. IMENSIONAL ® Figure 1 - SANITRON Dimensional Drawing ® Table 2 - SANITRON Dimensional Data...
  • Page 6: Installation

    Remove water purifi er from shipping carton. Inspect water purifi er, power cord and plug for damage. Do not operate if there is any damage to the purifi er, power cord or plug. Models S17A and S23A are shipped with the lamp already installed, while the lamp in the S37C and the S50C is packed separately.
  • Page 7: Recommended Options

    11. Once the plumbing hook ups are made, it is a good practice to disinfect the “downstream” plumbing between the purifi er and point of use. This is done by introducing chlorine into the purifi er chamber, a 100-ppm of chlorine is suggested. With the chlorine in the purifi...
  • Page 8: Optional Accessories

    If you encounter diffi culty due to deposits on the quartz sleeve, your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant. If quartz sleeve is clean (clear) then frequency of cleaning may be extended. NOTE: SANITRON ®...
  • Page 9: Disposal Of Mercury Added Lamp

    ISPOSAL OF ERCURY DDED AMPS Germicidal ultraviolet lamps, like standard fl uorescent lamps contain small amounts of mercury. Mercury added lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and recycling of lamps containing mercury, along with Federal and State requirements visit http://www.lamprecycle.org.
  • Page 10: Mechanism

    UARTZ LEEVE LEANING USING IPER ECHANISM Figure 4 - Quartz Sleeve Cleaning Step 1 - Lift wiper clip up Step 2 - Gently pull wiper knob out Step 3 - Push wiper back in Routine cleaning of the quartz sleeve is easily accomplished, using the dual action wiper mechanism. Lift wiper clip up and away from wiper rod.
  • Page 11: Replacement

    UARTZ LEEVE NSTALLATION OR EPLACEMENT Figure 5 - Quartz Sleeve Cleaning or Replacement Step 4 - Remove Gland Nuts Step 5 - Remove Washer & O - Rings Step 6 - Remove Quartz Sleeve SAFETY EQUIPMENT REQUIRED TO PERFORM TASK WARNING: Disconnect power to water purifi...
  • Page 12: Eplacement Of

    • Models S17A, and S23A, the ballast housing is mounted to the purifi er chamber using four (4) No. 8 x 3/8” long screws. Using a Phillips cross point screwdriver, carefully remove the four (4) screws, from along the sides of the ballast housing, and set aside.
  • Page 13: Optional Guardian

    12. Re-install o-rings, Tefl on® washers, and static gland nuts. Be sure o-rings are placed on quartz sleeve before Tefl on® washer. Tighten static gland nuts fi rmly by hand only, DO NOT USE HAND TOOLS. Tightening with hand tools is likely to cause quartz sleeve to break.
  • Page 14: Troubleshooting

    TROUBLESHOOTING WARNING: Always disconnect power to the water purifi er before performing any service or maintenance. IMPORTANT: This unit is to be serviced ONLY by qualifi ed, and appropriately licensed, personnel. Table 4 - Troubleshooting Problem Possible Cause Corrective Action Verify that the purifi...
  • Page 15: Technical Specifications

    TECHNICAL SPECIFICATIONS Table 5 - Technical Specifi cations Model: S17A S23A S37C S50C Flow Rate (GPM): Inlet\Outlet Size: 3/4”m NPT 3/4”m NPT 1”m NPT 1-1/2”m NPT Number of Lamps: 05-1098-R 05-1097-R 05-1343-R 05-1334-R Lamp Model No.: Length: 17-3/8” 23-3/8” 37-3/8”...
  • Page 16: Replacement Parts

    REPLACEMENT PARTS ® SANITRON S17A & S23A ODELS Figure 9 - Exploded View S17A & S23A...
  • Page 17: S17A & S23A

    Table 6 - Replacement Parts S17A & S23A S17A S23A Item No. Description Quantity Part Number Quantity Part Number Easy-Off End Cap 25-1499A1 25-1499A1 Rubber O-ring, Static Gland 00-1108B 00-1108B Lamp Spacer 25-0210A 25-0210A Lead Wire & Socket 05-1219B2 05-2223A...
  • Page 18: Sanitron Models S37C & S50C

    ® SANITRON S37C & S50C ODELS Figure 10 - Exploded View S37C & S50C...
  • Page 19: Replacement Parts

    Table 7 - Replacement Parts S37C & S50C S37C S50C Item No. Description Quantity Part Number Quantity Part Number Easy-Off End Cap 25-1499A1 25-1499A1 Rubber O-ring, Static Gland 00-1108B 00-1108B Lamp Spacer 25-0210A 25-0210A Lead Wire & Socket 05-1218A2 05-1218A2 Lamp 05-1343-R 05-1334-R...
  • Page 20: User Assistance

    E-mail: info@ultraviolet.com ® our offi ces, weekdays between 8:30 am and maintenance of the SANITRON Website: www.ultraviolet.com and 5:00 pm Eastern Time, at: Ultraviolet Water Purifi ers www.buyultraviolet.com PRODUCT REGISTRATION Please REGISTER your product immediately - you can do this in a number of ways.