® U LT R AV I O L E T WAT E R P U R I F I E R S Models S2400C, S5,000C - S25,000C High Capacity Systems Read and Follow All Safety Instructions. Save These Instructions. Installation, Operation &...
These instructions generally describe the installation, operation and maintenance of the SANITRON Model S2400C line of water purifiers. Models S5,000C and S10,000C through S25,000C High-Capacity Systems utilize the Model S2400C single lamp water purifier in various configurations. Questions that are not specifically answered by these instructions should be directed to the Factory.
SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
European Norm (EN) standards to which these units were tested, to demonstrate conformity. RINCIPLE OF PERATION The SANITRON ® design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to ultraviolet disinfection, is a function of time and the intensity of ultraviolet radiation to which the water is exposed.
Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the purified water being re-contaminated by bacteria in any of these units. Figure 1 - SANITRON ® Drawing (S5,000C shown) with options and extra components * Extra Components (not included with SANITRON ®...
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there is any damage to the purifier, power cord or plug. SANITRON ® Model S2400C is shipped with the lamp packed separately.
The water purifier must be connected to the cold water line only. Installation requires that a 5-micron sediment filter or finer be installed, in line, prior to the water purifier. The sediment filter will stop or trap large particulates from entering the water purifier. Particulates may cause damage to the quartz sleeve, as well as interfere with the purifier’s ability to disinfect the water.
The time delay mechanism is used in conjunction with, and is electrically connected to the Solenoid Valve. Wall Mount Kit: Model S2400C Stainless steel wall brackets provide quick and easy installation and professional finish. Pre-drilled and ready to install. Optimizes free air circulation to cool ballast housing.
ISPOSAL OF ERCURY DDED AMPS Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and recycling of lamps containing mercury, along with Federal and State requirements visit http://www.lamprecycle.org. Product Data ®...
NSTALLATION OR EPLACEMENT Figure 5 - Lamp Replacement Step 2 - Remove End -Cap Step 3 - Withdraw Lamp Step 4 & 5 - Remove Sockets Step 6 - Remove Lamp SAFETY EQUIPMENT REQUIRED TO PERFORM TASK WARNING: Disconnect power to water purifier. Remove both EASY-OFF end caps by pulling each cap off static gland nut.
• Model S2400C the ballast housing is mounted to the purifier chamber using four (4) 1/4”-20 x 3/8” long hex head bolts. Using a 7/16” wrench or an adjustable wrench, carefully remove the four (4) bolts with the lock and flat washers, from along the top of the ballast housing, and set aside.
12. Re-install o-rings, Teflon ® washers, and static gland nuts. Be sure o-rings are placed on quartz sleeve before Teflon ® washer. Tighten static gland nuts firmly by hand only, DO NOT USE HAND TOOLS. Tightening with hand tools is likely to cause quartz sleeve to break.
Optional Accessories Available For: operation at 120v 60Hz or 220v 50Hz. Please specify. Guardian™ Ultraviolet Monitor - Analog/Digital S2400C, S5,000C - S25,000C Not all options may be available Sentry™ Safety Sensor S2400C, S5,000C - S25,000C for all models, consult factory for availability Steralert™...
Table 5 - Replacement Parts S2400C 120v/60Hz 220-240v/50Hz CE/RoHS 220-240v Item No. Description Part Number Part Number Part Number Easy-Off End Cap 25-0389A 25-0389A 25-0389A Rubber O-Ring, Static Gland 00-0085A 00-0085A 00-0085A Lead Wire & Socket 05-2400A 05-2400A 05-2400A Static Gland Nut...
This manual Fax: 631.273.0771 installation or use of this unit, contact describes the installation, operation E-mail: info@ultraviolet.com and maintenance of the SANITRON ® our offices, weekdays between 8:30 am Website: www.ultraviolet.com and 5:00 pm Eastern Time, at: Ultraviolet Water Purifiers www.buyultraviolet.com...