Charging the Battery
WARNING
Charging the battery produces gasses that can
explode.
Never smoke near the battery and keep sparks and
flames away from battery.
Important: Always keep the battery fully charged. This
is especially important to prevent battery damage when
the temperature is below 32°F (0°C).
1. Charge battery for 10 to 15 minutes at 25 to 30 amps
or 30 minutes at 10 A.
2. When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the charger
leads from the battery posts
3. Install the battery in the machine and connect the
battery cables.
Figure 44
1. Positive battery post
2. Negative battery post

Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Note: The fuses are located on right hand console next to
the seat
(Figure
45).
Fuse type:
Main—30 A, blade-type
Engine—20 A, blade-type
1. To replace the main fuse, grasp the fuse and pull it
straight and away from the fuse block
(Figure
44).
3. Red (+) charger lead
4. Black (-) charger lead
(Figure
45).
1. Fuse block
Important: Ensure that the new fuses are the
same type and amperage as the fuses removed.
2. To replace the engine fuse, remove the console from
the plastic fender.
1. Engine fuse—25 A
3.
Grasp the engine fuse and pull it straight and away
from the fuse block
4. Align a new fuse with the slot in the fuse block
45).
5. Push the fuse into the fuse block until the fuse is seated
(Figure
45).
36
2
1
Figure 45
2. Main—30 A
Figure 46
(Figure
46).