QuickSpecs
Technical Specifications
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500
LED Indicators on Front
LED Indicators on Front
LED Indicators on Front
LED Indicators on Front
(3)
LED Indicators for Drive
LED Indicators for Drive
LED Indicators for Drive
LED Indicators for Drive
Modules (3)
Modules
Modules
Modules
LED Indicators on Rear
LED Indicators on Rear
LED Indicators on Rear
LED Indicators on Rear
Panel (4)
Panel
Panel
Panel
Interface
Interface
Interface
Interface
Maximum Number of
Maximum Number of
Maximum Number of
Maximum Number of
Drives
Drives
Drives
Drives
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
Input Power Requirements Rated Input Voltage
Input Power Requirements
Input Power Requirements
Input Power Requirements
Heat Dissipation
Heat Dissipation
Heat Dissipation
Heat Dissipation
(maximum)
2-Port SCSI I/O Module
2-Port SCSI I/O Module
2-Port SCSI I/O Module
2-Port SCSI I/O Module
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500
Cabinet
Cabinet
Cabinet
Cabinet
Shipping Packaging
Shipping Packaging
Shipping Packaging
Shipping Packaging
Power
Fault detected in one or more sub-systems
Fault in Enclosure Management
Drive Access (centre)
Online (left)
Drive Failure (right)
Power Supply/Blower Assembly Fault (1)
EMU (3): Power; A bus; B bus
Ultra3 SCSI to Hard Drives
Ultra3 SCSI to Host Servers
14, 1-in Ultra320, Ultra3 or Ultra2 Universal Hard Drives (Modular Smart Array 500 cabinet)
Operating
Operating
Operating
Operating
Shipping
Shipping
Shipping
Shipping
Operating
Operating
Operating
Operating
Non-operating
Non-operating
Non-operating
Non-operating
Rated Input Voltage
Rated Input Voltage
Rated Input Voltage
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
Rated Input Current
Rated Input Current
Rated Input Current
Rated Input Current
Input Power
Input Power (max)
Input Power
Input Power
1876 Btu/hr*
*Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full rated
power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration.
Ports
Ports
Ports
Ports
Dimensions
Dimensions
Dimensions
Dimensions
Weight
Weight
Weight
Weight
4U Rack Form Factor
Dimensions
Dimensions (H x W x D)
Dimensions
Dimensions
Weight (Net)
Weight
Weight
Weight
Dimensions
Dimensions
Dimensions (L x W x D)
Dimensions
Weight (Gross)
Weight
Weight
Weight
DA - 11050
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
50° to 95° F (10° to 35° C)
-2° to 122° F (-0° to 50° C)
NOTE:
NOTE:
NOTE:
NOTE: Rated 1°C per 1000 feet of elevation to 10000 ft.
10% to 90%
Up to 95%
100 to 240 VAC
50 to 60 Hz
2.3 A at12 VAC typical, 6A Maximum
549 W*
2 VHDCI Ultra3 SCSI ports
4.5 x 1.375 x 9.5 in (11.4 x 3.5 x 24.1 cm)
1.3 lb (0.6 Kg)
6.9 x 19 x 20.5 in (17.5 x 48.3 x 52.1 cm)
50 lb (22.5 kg)
33.7 x 14.8 x 33.8 in (85.6 x 37.5 x 85.9 cm)
70 to 105 lb (31.5 kg)
Canada — Version 13 — July 19, 2004