Maintenance; General Comments - Ariston GENUS HE SYSTEM 24 Installation And Servicing Instrucnions

Gas fired condensing wall hung combination boilers
Hide thumbs Also See for GENUS HE SYSTEM 24:
Table of Contents

Advertisement

maintenance

Important
Maintenance is an essential part of the safe and efficient operation
of the boiler and ensures its durability. It should be performed
according to the instructions given in current legislation. Perform
combustion analysis regularly in order to check the operating
efficiency of the boiler and to make sure any polluting substances
relased are within the boundaries set by current legislation.
Before beginning maintenance work:
-
Disconnect the appliance from the electricity supply by
turning the external bipolar switch to the "OFF" position;
-
Close the gas valve and the central heating and domestic hot
water system valve.
After the work has been completed the initial settings will be
restored.

General comments

It is recommended that the following inspections be carried out
on the boiler at least once a year:
1.
Check the seals in the water part and, if necessary, replace the
gaskets and restore the seal to perfect working order.
.
Check the seals in the gas part and, if necessary, replace the
gaskets and restore the seal to perfect working order.
3.
Visually check the overall condition of the boiler.
4.
Visually check the combustion and, if necessary, disassemble
and clean the burner.
5.
Following the inspection detailed in point "3", disassemble
and clean the combustion chamber, if necessary.
6.
Following the inspection detailed in point "4", disassemble
and clean the burner and injector, if necessary.
7.
Cleaning the primary heat exchanger
8.
Make sure the following heating safety devices are operating
correctly:
- temperature limit safety device.
9.
Make sure that the following gas part safety devices are
operating correctly:
- absence of gas or flame safety device (ionisation).
10. Perform a general inspection of the boiler operation.
11. Remove oxide from the detection electrode using an emery
cloth.
1. These checks are not exhaustive. Further mechanical, electrical
and combustion maintenance checks may be required.
Operational test
After having carried out the maintenance operations, fill the
heating circuit at a pressure of approximately 1.0 bar and release
the air from the system.
- Begin operating the boiler.
- If necessary, release the air from the heating system again.
- Check the settings and make sure all the command, adjustment
and monitoring parts are working correctly.
- Check the flue system is sealed and operating correctly.
46
Supplied By www.heating spares.co Tel. 0161 620 6677
Draining procedures
The heating system must be drained using the following
procedure:
- Switch off the boiler, make sure the external bipolar switch is in
the OFF position and shut off the gas valve;
- Loosen the automatic air relief valve;
- Open the system drain off cock and collect the escaping water
in a container;
- Empty the water from the lowest points of the system (where
applicable).
If the system is to be left inactive in areas where the room
temperature may fall below 0°C during winter, we recommend
that anti-freeze liquid is added to the water in the heating system
in order to avoid the need for repeated draining; when this liquid
is used make sure it is compatible with the stainless steel used for
the bodywork of the boiler.
We recommend the use of anti-freeze products which contain
PROPYLENE GLYCOLS as these inhibit corrosion and that they
are used in conjunction with the anti-scaling and anti-corrosion
function, in the quantities suggested by the manufacturer, at the
mimimum temperature.
Regularly check the pH level of the water/anti-freeze mix in the
boiler circuit and replace it when the value measured is lower than
the limit prescribed by the manufacturer.
DO NOT MIX DIFFERENT TYPES OF ANTI-FREEZE.
The manufacturer will not be held liable for any damage caused
by the appliance or the system due to the use of inappropriate
anti-freeze substances or additives.
WARNING
Before handling, empty all components which may contain hot
water, emptying where necessary.
Descale the components in accordance with the instructions
provided on the safety data leaflet supplied with the product used,
make sure the room is well ventilated, wear protective clothing,
avoid mixing different products, and protect the appliance and
surrounding objects.
Seal all openings used to take a gas pressure reading or to make
any gas adjustments.
Make sure that the nozzle is compatible with the supplied gas.
If a smell of burning is detected or smoke is seen leaking from
the appliance, or there is a smell of gas, disconnect it from the
electricity supply, shut off the gas valve, open the windows and
call for technical assistance.
Cleaning the primary exchanger
Cleaning the smoke side
The inside of the primary exchanger is accessed by removing the
burner. Wash with water and detergent using a non-metallic rifle-
type brush, rinse with water.
Cleaning the trap
The trap is accessed by emptying the condensate bowl located in
the bottom section. Wash with water and detergent.
Replace the condensate collection bowl in its housing.
NB: in the event of prolonged use of the appliance, the trap must
be filled before being used again.
A lack of water in the trap is dangerous and may cause smoke to
be released into the atmosphere.