If you smell gas or are worried about gas safety, you can call the National Gas Emergency Service free on
0800 111 999
at any time, day or night.
Key to symbols:
Failure to comply with this warning implies the risk of personal injury, in some circumstances even fatal
Failure to comply with this warning implies the risk of damage, in some circumstances even serious, to property, plants or animals.
Do not perform operations which involve opening the appliance.
Explosions, fires or intoxication caused by gas leaking from disconnected piping.
Damage to the appliance or items underneath it caused by the object falling off as a result of vibrations.
THE INSTALLATION AND FIRST IGNITION OF THE BOILER MUST BE PERFORMED BY QUALIFIED GAS SAFE REGISTERED ENGINEER IN COMPLIANCE WITH GAS SAFETY (INSTILLATION & USE) REGULATIONS AND ALL OTHER NATIONAL REGULATIONS REGARDING INSTALLATION, AND IN CONFORMITY WITH ANY REQUIREMENTS ESTABLISHED BY LOCAL AUTHORITIES AND PUBLIC HEALTH ORGANISATIONS.
AFTER THE BOILER HAS BEEN INSTALLED, THE INSTALLER MUST ENSURE THAT THE END USER RECEIVES THE DECLARATION OF CONFORMITY AND THE OPERATING MANUAL, AND SHOULD PROVIDE ALL NECESSARY INFORMATION AS TO HOW THE BOILER AND THE SAFETY DEVICES SHOULD BE HANDLED.
This appliance is designed to produce hot water for domestic use (combi version).
It should be connected to a heating system and a distribution network for domestic hot water, both of which must be compatible with its performance and power levels. The use of the appliance for purposes other than those specified is strictly forbidden. The manufacturer cannot be held responsible for any damage caused by improper, incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual. Installation, maintenance and all other interventions must be carried out in full conformity with the governing legal regulations and the instructions provided by the manufacturer. Incorrect installation can harm persons, animals and possessions; the manufacturing company shall not be held responsible for any damage caused as a result. In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories, switch the appliance off by switching the external bipolar switch to the "OFF" position and shutting off the gas valve.
When the work has been completed, ask a qualified technician to check the efficiency of the ducting and the devices. If the boiler should be out of use for a prolonged period, it is recommended that the electrical power supply be disconnected and that the external gas cock be closed. If low temperatures are expected, the boiler and system pipe work should be drained in order to prevent frost damage. Turn the boiler off and turn the external switch "OFF" to clean the exterior parts of the appliance.
Do not allow children or inexperienced persons to use the appliance without supervision.
Legend:
Legend:
Digits indicating:
Technical assistance request
Flame detected with indication of power used
Heating operation set
Heating operation active
Hot Water Comfort activated
Boiler off with antifreeze function active
Anti-frost Function Active
AUTO function activated
High efficiency operation (low C.H. flow temperature)
Solar temperature probe connected - option
Error signals
The display shows the code
External temperature displayed (with external sensor optional)
Wi-Fi active (Kit Optional)
Check the water pressure on the system pressure gauge and make sure that the figure is between 0.6 and1.5 bar when the system is cold.
ATTENTION
DEAERATION CYCLE
THE DEAERATION CYCLE IS AUTOMATICALLY ACTIVATED WHEN THE BOILER IS POWERED ON FOR THE FIRST TIME. THE DISPLAY SHOWS "PURGE". AT THE END OF THE FUNCTION (7 MINUTES) THE DISPLAY RETURNS TO NORMAL VIEW.
Press the ON/OFF button on the control panel to switch on the boiler
The display shows:
It is possible to set the temperature of the heating water by pressing the buttons 8.
The temperature that may be obtained.which varies from 20°C to 45°C (low temperature) and 35°C to 82°C (high temperature).
The ignition of the burner is indicated on the display by the symbol the dashes underneath indicate the power utilised.
To switch off the heating, press the ON/OFF button; the display will switch off.
THE ANTI-FROST FUNCTION REMAINS ACTIVE.
ATTENTION
SWITCH OFF THE BOILER COMPLETELY BY SWITCHING THE EXTERNAL ELECTRICAL SWITCH TO THE OFF POSITION. SHUT OFF THE GAS VALVE.
The AUTO function enables boiler operation to be adapted to environmental conditions and to the type of system it is installed on.
Comfortable temperature is reached inside the room in the quickest way possible, without wasting money, energy or efficiency, while substantially reducing the amount of wear experienced by the components.
Your installer will advise you on the devices connectable to the boiler and will program it according to the system.
In normal boilers the water temperature inside the heating elements is usually set to a high value (70-80°C), thereby ensuring effective heating during the few really cold winter days. It then becomes excessive on less cold days (of which there are many) more typical of the autumn and winter seasons. This leads to excessive room heating after the thermostat has been switched off, resulting in energy waste and uncomfortable conditions inside the room. The AUTO function "takes control" of the boiler and selects the best operating regime based on environmental conditions, external devices connected to the boiler and the performance required. It constantly decides at which power level to operate based on the environmental conditions and the room temperature required.
The boiler is protected from malfunctions by means of internal checks performed by the electronic P.C.B., which stops the boiler from operating if necessary. In the event of the boiler being shut off in this manner, a code appears on the control panel display which refers to the type of shut-off and the reason behind it. Two types of shut-off may occur:
This type of error is "volatile", which means that the boiler starts up again automatically as soon as the problem which caused the shut-off is removed;
and the error code (e.g.
) flash on the display and the
symbol appears.
In fact, soon as the cause of the shut-off disappears, the boiler starts up again and continues to operate normally.
If the boiler still indicates a safety shut-off, switch it off. Make sure the external electric switch is in the OFF position, shut off the gas valve and contact a qualified technician.
This type of error is "non-volatile", which means that it is not removed automatically.
On the display flash and the error code, e.g. Err/501 and appears the symbol
.
In this case the boiler does not restart automatically, but it may be reset by pressing the button.
If the problem manifests itself again after several attempts to reset the appliance, contact a qualified technician.
If this shutdown occurs frequently, contact an authorised service centre for assistance. For safety reasons, the boiler will allow a maximum of 5 reset operations to take place in 15 minutes (individual presses of the button). If the shutdown is occasional or an isolated event, this is not Necessarily a problem.
Display | Description |
1 01 | Overheating |
1 03 | Insufficient circulation |
1 04 | |
1 05 | |
1 06 | |
1 07 | |
3 05 | P.C.B. error |
3 06 | P.C.B. error |
3 07 | P.C.B. error |
5 01 | No flame detection |
The anti-frost function acts on the central heating flow temperature probe, independently from other settings, when the electrical supply is turned on.
If the primary circuit temperature falls below 8°C the pump will run for 2 minutes.
After the two minutes of circulation (fixed) the boiler will check the following:
The anti-frost device activates only when (with the boiler operating correctly):
Our boilers are designed to function either with Natural Gas (Methane, G20) or LPG (Propane, G31).
If you need to change from one gas to another then you should speak to a Gas Safe Registered engineer or please call Ariston on 0333 240 8777.
Schedule an annual service for the boiler with a Gas Safe Registered engineer. Correct maintenance always results in savings in the cost of running the system. Failure to arrange an annual service for the appliance will invalidate the warranty of the appliance.
Registration is online at www.ariston.com/uk
* The installation must have been carried out by a Gas Safe Registered engineer. For more information call us on 0333 240 8777.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.