The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most
likely cause is listed first, in boldface type.
Note: Do the FRU replacement or other actions in the sequence shown in the column headed "FRU or
action, in sequence." If replacing a FRU does not solve the problem, put the original part back in the tablet.
Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to be replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays, n can
be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not
described there, go to "Intermittent problems" on page 33.
Note: For a device not supported by diagnostic codes in the ThinkPad tablet computers, see the manual for
that device.

Error codes

Table 2. Error codes
Symptom or error
0177
Bad SVP data, stop POST task—The checksum of the
supervisor password in the EEPROM is not correct.
0183
Bad CRC of Security Settings in EFI Variable. Enter
ThinkPad Tablet Setup.
0187
EAIA data access error.
0188
Invalid RFID Serialization Information Area.
0189
Invalid RFID configuration information area.
0190
Critical low-battery error.
0191
System Security—Invalid Remote Change requested.
0199
System Security - Security password retry count
exceeded.
0270
Real Time Clock Error.
0271
Check Date and Time settings.
32
ThinkPad X1 Tablet Hardware Maintenance Manual
FRU or action, in sequence
Replace the system board. Have the tablet serviced.
Checksum of the Security settings in the EFI Variable
is not correct. Enter ThinkPad Tablet Setup to check
Security settings. Press F10, and then press Enter to
restart the system. If your tablet still has a problem, have
the tablet serviced.
The access to EEPROM is failed. Have the tablet serviced.
The EEPROM checksum is not correct (block # 0 and 1).
The system board should be replaced, and the box serial
number should be reinstalled. Have the tablet serviced.
The EEPROM checksum is not correct (block # 4 and
5). The system board should be replaced, and the UUID
should be reinstalled. Have the tablet serviced.
The tablet turned off, because the battery is low. Connect
the ac power adapter to the tablet and charge the battery.
The system configuration change has failed. Confirm the
operation and try again. To clear the error, enter ThinkPad
Tablet Setup.
This message is displayed if you enter a wrong supervisor
password more than three times. Confirm the supervisor
password and try again. To clear the error, enter the
ThinkPad Tablet Setup.
System Real Time Clock is not functional. Have the tablet
serviced.
Neither the date nor the time is set in the tablet. Set the
date and time, using the ThinkPad Tablet Setup program.