Daikin FXHQ32MVE Installation Manual
Hide thumbs Also See for FXHQ32MVE:

Advertisement

SYSTEM
MODELS
Ceiling suspended type
FXHQ32MVE
FXHQ63MVE
FXHQ100MVE
CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE HINWEISE VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG AN EINEM LEICHT ZUGÄNGLICHEN ORT FÜR
SPÄTERES NACHSCHLAGEN AUF.
VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVEZ CE MANUEL EN LIEU SÛR POUR POUVOIR VOUS Y REPORTER
ULTÉRIEUREMENT.
LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA INSTALACIÓN.
CONSERVE ESTE MANUAL PARA POSIBLES CONSULTAS FUTURAS.
PRIMA DELL'INSTALLAZIONE, LEGGERE ATTENTAMENTE LE PRESENTI ISTRUZIONI.
CONSERVARE IL PRESENTE MANUALE IN UN LUOGO FACILMENTE ACCESSIBILE PER
RIFERIMENTO FUTURO.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ.
ΦΥΛΑΞΤΕ ΑΥΤΟ ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΣΕ ΒΟΛΙΚΟ ΜΕΡΟΣ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ.
LEES DEZE INSTRUCTIES ZOGVULDIG DOOR VOORDAT MET DE INSTALLATIE WORDT
BEGONNEN.
BEWAAR DEZE HANDLEIDING VOOR TOEKOMSTIG GEBRUIK OP EEN GESCHIKTE
PLAATS ONDER HANDBEREIK.
LEIA ATENTAMENTE ESTAS INSTRUÇÕES ANTES DA INSTALAÇÃO.
MANTENHA ESTE MANUAL NUM LOCAL DE FÁCIL ACESSO PARA CONSULTA.
ПЕРЕД УСТАНОВКОЙ ВНИМАТЕЛЬНО ПРОЧИТАЙТЕ ДАННЫЕ ИНСТРУКЦИИ.
ХРАНИТЕ ДАННОЕ РУКОВОДСТВО В ЛЕГКО ДОСТУПНОМ МЕСТЕ ДЛЯ ЕГО
ПОСЛЕДУЮЩЕГО ИСПОЛЬЗОВАНИЯ.

INSTALLATION MANUAL

FXHQ32MAVE
FXHQ63MAVE
FXHQ100MAVE
Air Conditioners
English
Deutsch
Français
Español
Italiano
ëëçíéêÜ
Nederlands
Português
óññêèé

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FXHQ32MVE

  • Page 1: Installation Manual

    INSTALLATION MANUAL English SYSTEM Air Conditioners Deutsch MODELS Français Ceiling suspended type FXHQ32MVE FXHQ32MAVE FXHQ63MVE FXHQ63MAVE Español FXHQ100MVE FXHQ100MAVE Italiano CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. ëëçíéêÜ LESEN SIE DIESE HINWEISE VOR DER INSTALLATION SORGFÄLTIG DURCH.
  • Page 2 3P109591-1E...
  • Page 3: Table Of Contents

    VRV SYSTEM Air Conditioners Installation manual CONTENTS • Be sure to use only the specified parts and accessories for installation work. 1. SAFETY PRECAUTIONS..........1 Failure to use the specified parts may result in the air condi- 2. BEFORE INSTALLATION..........2 tioner falling down, water leakage, electric shocks, a fire, etc.
  • Page 4: Before Installation

    • Install the air conditioner, power supply wiring, remote control- PRECAUTIONS ler wiring and transmission wiring at least 1 meter away from • Be sure to read this manual before installing the indoor unit. televisions or radios to prevent image interference or noise. •...
  • Page 5: Selecting Installation Site

    SELECTING INSTALLATION SITE FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK (1) Select an installation site where the following condi- AFTER INSTALLATION IS FINISHED. tions are fulfilled and that meets your customer’s approval. a. Items to be checked after completion of work •...
  • Page 6: Preparations Before Installation

    PREPARATIONS BEFORE INSTALLA- TION (1) Relative positions of indoor unit, suspension bolt, pip- ing hole, drain piping hole, and electric wire hole posi- tion. (Refer to Fig. 2) ront view ig. 4 Left side piping hole Rear side piping hole 2) Detach the dressing boards (left and right).
  • Page 7: Indoor Unit Installation

    4) Set the suspension bolt. (Use W3/8 or M8-M10 size sus- (5) When hanging the indoor unit main body, be sure to pension bolts.) use a level or a plastic tube with water in it to make sure • Adjust the distance from the unit to the ceiling slab the drain piping is set either level or slightly tilted, in beforehand.
  • Page 8 (1) In case of backward piping op penetration • Remove the rear cover for piping. (Refer to Fig. 12, 14) lid cramp section hermistor lead line (2) In case of upward piping Clamp • In case of upward piping, optional L-shape piping kit is required.
  • Page 9: Drain Piping Work

    Use “ Table 2 ” as a reference if a torque wrench is not available. NOTE NOTE NOTE NOTE Once work is complete, make sure there is no gas leaking. As The flare nuts used must be those included with the main the flare nut is tightened with the wrench, the torque will sud- body.
  • Page 10: Electric Wiring Work

    • For left drain pipe outlet, remove the rubber plug and the NOTE NOTE NOTE NOTE insulation on the drain pipe connecting opening on the • To ensure no excessive pressure is applied to the included left side of the unit and change the position to the right drain hose (1), do not bend or twist when installing.
  • Page 11: Wiring Example And How To Set The Remote Controller

    • Multiple number of indoor units are connected to one outdoor NOTE NOTE NOTE NOTE unit. Name each indoor unit as A-unit, B-unit ….. and the like. 1. Shows only in case of protected piping. Use H07RN-F in When these indoor units are wired to the outdoor unit and the case of no protection.
  • Page 12 CAUTION WARNING • Be sure to attach the sealing material or putty (field supplied) • When wiring, form the wirings orderly so that the control box to hole of wiring to prevent the infiltration of water as well as lid can be securely fastened. If the control box lid is not in any insects and other small creatures from outside.
  • Page 13 When including BS unit (2) Turn the MAIN/SUB changeover switch on one of the two remote controller PC boards to “S”. (Leave the switch of the Power other remote controller set to “M”.) Outdoor unit supply 220-240V Control box IN/D OUT/D 50Hz BS unit BS unit...
  • Page 14: Installation Of The Suction Grille And The Air Filter

    10. INSTALLATION OF THE SUCTION • When in the field set mode, select mode No. 12, then set the first code (switch) No. to “1”. Then set second code GRILLE AND THE AIR FILTER (position) No. to “01” for FORCED OFF and “02” for ON/ Install side panel and suction grille properly in the order oppo- OFF OPERATION.
  • Page 15 3P172532-7B EM02A086D (1511) HT...

This manual is also suitable for:

Fxhq63mveFxhq32maveFxhq63maveFxhq100maveFxhq100mve

Table of Contents