Daikin FXHQ32AVEB Installation Manual
Hide thumbs Also See for FXHQ32AVEB:

Advertisement

SYSTEM
MODELS
(Ceiling Suspended type)
FXHQ32AVEB
FXHQ63AVEB
FXHQ100AVEB
CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE HINWEISE VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG AN EINEM LEICHT ZUGÄNGLICHEN ORT FÜR SPÄTERES
NACHSCHLAGEN AUF.
VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVEZ CE MANUEL EN LIEU SÛR POUR POUVOIR VOUS Y REPORTER ULTÉRIEURE-
MENT.
LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA INSTALACIÓN
CONSERVE ESTE MANUAL PARA POSIBLES CONSULTAS FUTURAS.
PRIMA DELL'INSTALLAZIONE, LEGGERE ATTENTAMENTE LE PRESENTI ISTRUZIONI.
CONSERVARE IL PRESENTE MANUALE IN UN LUOGO FACILMENTE ACCESSIBILE PER RIFERI-
MENTO FUTURO.
ΔΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟΔΗΓΙΕΣ ΠΡΙΝ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
ΦΥΛΑΞΤΕ ΑΥΤΟ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΣΕ ΒΟΛΙΚΟ ΜΕΡΟΣ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ.
LEES DEZE INSTRUCTIES ZOGVULDIG DOOR VOORDAT MET DE INSTALLATIE WORDT BEGON-
NEN.
BEWAAR DEZE HANDLEIDING VOOR TOEKOMSTIG GEBRUIK OP EEN GESCHIKTE PLAATS
ONDER HANDBEREIK.
LEIA ATENTAMENTE ESTAS INSTRUÇÕES ANTES DA INSTALAÇÃO.
MANTENHA ESTE MANUAL NUM LOCAL DE FÁCIL ACESSO PARA CONSULTA.
ПЕРЕД УСТАНОВКОЙ ВНИМАТЕЛЬНО ПРОЧИТАЙТЕ ДАННЫЕ ИНСТРУКЦИИ.
ХРАНИТЕ ДАННОЕ РУКОВОДСТВО В ЛЕГКО ДОСТУПНОМ МЕСТЕ ДЛЯ ЕГО ПОСЛЕДУЮЩЕГО
ИСПОЛЬЗОВАНИЯ.
MONTAJDAN ÖNCE BU YÖNERGELERİ DİKKATLİCE OKUYUN
DAHA SONRA BAKMAK ÜZERE BU KILAVUZU SAKLAYIN

INSTALLATION MANUAL

Air Conditioners
English
Deutsch
Français
Español
Italiano
Ελληνικά
Nederlands
Portugues
Ðóññêèé
Türkçe

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FXHQ32AVEB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin FXHQ32AVEB

  • Page 1: Installation Manual

    INSTALLATION MANUAL English SYSTEM Air Conditioners Deutsch MODELS Français (Ceiling Suspended type) FXHQ32AVEB FXHQ63AVEB Español FXHQ100AVEB Italiano Ελληνικά CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. LESEN SIE DIESE HINWEISE VOR DER INSTALLATION SORGFÄLTIG DURCH.
  • Page 2: Table Of Contents

    FXHQ32AVEB FXHQ63AVEB VRV SYSTEM Air Conditioners Installation manual FXHQ100AVEB CONTENTS • Consult your dealer regarding what to do in case of refrigerant leakage. 1. SAFETY PRECAUTIONS ..........1 When the air conditioner is installed in a small room, it is 2. BEFORE INSTALLATION..........2 necessary to take proper measures so that the amount of 3.
  • Page 3: Before Installation

    • For selection of installation location, use the installation CAUTION pattern paper (used in common with the packing case.) as • Install drain piping according to this installation manual to reference. • Do not use the air conditioner where in the salty atmosphere ensure good drainage, and insulate the piping to prevent such as coastal areas, vehicles, vessels or the voltage condensation.
  • Page 4: Selection Of Installation Location

    CARRY OUT THE WORK GIVING CAUTION TO THE 2. Items to be checked at delivery FOLLOWING ITEMS AND AFTER THE WORK IS Check COMPLETED CHECK THESE AGAIN. Items to be checked column Have you carried out field setting? (if necessary) 1.
  • Page 5: Preparation Before Installation

    PREPARATION BEFORE INSTALLA- TION *30 or more *30 or more (1) For the locations of indoor unit hanging bolts, piping outlet holes, drain piping outlet hole, and electric wiring inlet hole. (Refer to Fig. 3) Fig. 1 Required installation space (mm) View from the front Left back drain Discharge...
  • Page 6: Installation Of The Indoor Unit

    (3) Remove the parts of the indoor unit. • Remove the fixture screw for hanger at the back side 1) Remove the suction grille. (M5), pull the hanger backward (the arrow direction) • Slide the suction grille fixing knobs (32 type: 2 places to remove.
  • Page 7: Refrigerant Piping Work

    CAUTION For safety, make sure to use a washer for hanger (3) ≤1° (accessory) and fix by double nuts firmly. (2) Lift up the indoor unit, slide from the front and put the hanger installing bolt (M8) into the securely for tempo- rary hanging.
  • Page 8 Do not mix substance other than the specified refriger- • If there is no torque wrench, use Table 2 as a rule of thumb. ant such as air into the refrigeration circuit. When tightening a flare nut with a spanner harder and If the refrigerant leaks during the work, ventilate the harder, there is a point where the tightening torque suddenly room.
  • Page 9 Piping insulating Rear piping penetration cover material Gas side piping insulating method Cutoff Top panel (indoor unit side) Joint insulating material (6) (accessory) Do not leave clearance Bring the seam Flare nut connection to the top View from air inlet side Cut at the position avoiding the knob part of the...
  • Page 10: Drain Piping Work

    • Before brazing refrigerant piping, have nitrogen flow through the refrigerant piping and substitute air with nitrogen. Then, Back side (sheet metal) carry out brazing (NOTE 2). (Refer to Fig. 20) After all the Detach parts brazing works are finished, carry out flare connection with the Putty or insulation indoor unit.
  • Page 11 • Bend the tip of the metal clamp (2) so that the sealing mate- • Install supports at a distance of 1 to 1.5m so that the piping rial does not bulge. (Refer to Fig. 26) may not deflect. (Refer to Fig. 23) •...
  • Page 12: Electric Wiring Work

    Fan motor supply However, it is not necessary to install the stay for packing and Voltage delivering at the right side (reinforcing plate). Model Volts range (Refer to Fig. 30) FXHQ32AVEB 0.060 220- Max. 264 FXHQ63AVEB 0.091 Min. 198 FXHQ100AVEB 0.150 MCA: Min.
  • Page 13 Connection of 2 Connection of 2 Connection of wirings on one side wirings of different wirings of same size Forbidden Terminal block for remote is prohibited. sizes is prohibited. must be carried out controller / transmission on both sides. Never connect the wiring (X1M) power supply wiring.
  • Page 14 Wiring fixture (11) (accessory)/ Power supply wiring Transmission wiring Screw for wiring fixture (12) and earth wiring Remote controller (accessory) and transmission wiring Remote controller wiring Putty or insulation (field supply) Clamp (4) (accessory) Power supply wiring and Earth wiring Resin bushing (10) (accessory) Wiring fixture (11) (accessory)/...
  • Page 15 << No. 3 system: When BS unit is used >> Indoor unit 1 Indoor unit 2 Indoor unit largest No. Power supply Outdoor unit BS unit 220-240V IN/D OUT/D OUT/D IN/D 50Hz Crossover wiring (Remote controller) Remote controller 1 (Main) Remote controller 2 (Sub) Fig.
  • Page 16: Mounting Suction Grille · Decoration Side Panel

    MOUNTING SUCTION GRILLE · DECO- 10-1 SETTING OF CEILING HEIGHT • Set the SECOND CODE No. according to the ceiling height RATION SIDE PANEL as shown in the Table 3. Install securely in the reverse order when decoration side panel (The SECOND CODE No.
  • Page 17: Wiring Diagram

    Table 5 To the operator carrying out test operation Filter hours FIRST SECOND After test operation is completed, before delivering the air Contamination Mode No. (long life type) CODE No. CODE No. conditioner to the customer, confirm that the control box lid, the Approx.
  • Page 18 Fig. 36 English...
  • Page 19 3P368557-2 EM12A009B (1502) HT...

This manual is also suitable for:

Fxhq63avebFxhq100aveb

Table of Contents