Daikin FXHQ-MAVE Series Technical Data Manual

Daikin FXHQ-MAVE Series Technical Data Manual

Ceiling suspended unit

Advertisement

technical data
Ceiling Suspended Unit
FXHQ-MAVE

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FXHQ-MAVE Series

  • Page 1 technical data Ceiling Suspended Unit FXHQ-MAVE...
  • Page 2: Table Of Contents

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE TABLE OF CONTENTS FXHQ-MAVE Specifications ............3 Technical Specifications .
  • Page 3 • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE ® • VRV Systems • Indoor Units...
  • Page 4: Specifications

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Specifications ® S u s t e m U n i A V E S y s o o r Q - M I n d V R V C e i F X H 1-1 TECHNICAL SPECIFICATIONS FXHQ32MAVE...
  • Page 5: Electrical Specifications (50Hz)

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Specifications 1-2 ELECTRICAL SPECIFICATIONS (50HZ) FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE Power Supply Name Phase Frequency Voltage 220-240 Current Minimum circuit amps (MCA) Maximum fuse amps (MFA) Full load amps (FLA) Voltage range Minimum -10% Maximum +10%...
  • Page 6: Safety Device Settings

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Safety device settings FXHQ32MA FXHQ63MA FXHQ100MA PC BOARD FUSE 250V 5A ±5 ±20 °C FAN MOTOR THERMAL PROTECTOR OFF: 130 / ON: 80 3D034597C Options FXHQ32MA FXHQ63MA FXHQ100MA DRAIN PUMP KIT KDU50M60VE KDU50M125VE KDU50M125VE...
  • Page 7: Capacity Tables

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Capacity tables 5 - 1 Cooling capacity tables FXHQ-MA TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp. 20.0DB 23.0DB 26.0DB...
  • Page 8: Heating Capacity Tables

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Capacity tables 5 - 2 Heating capacity tables FXHQ-MA Indoor air temperature ƒCDB Outdoor Unit Size Nominal capacity 16.0 18.0 20.0 21.0 22.0 24.0 air temperature ƒCDB ƒCWB -19.8 -20.0 -18.8 -19.0 -16.7 -17.0...
  • Page 9: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXHQ32MA Position slit hole for taking out in piping back (View from the front) (Hanging position) Hanging bolt 4 - M8~M10 Position: hole of wall for taking out in piping back (View from the front)
  • Page 10 • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXHQ100MA Position slit hole for taking out in piping back (View from the front) Hanging bolt (Hanging position) 4 - M8~M10 Position: hole of wall for taking out in piping back (View from the front)
  • Page 11: Piping Diagram

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Piping diagram FXHQ-MA Gas pipe connection port Heat exchanger Liquid pipe connection port Filter Filter Electronic expansion valve 4D034245A ® • VRV Systems • Indoor Units...
  • Page 12: Wiring Diagram

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Wiring diagram 8 - 1 Wiring diagram FXHQ-MA Note 2 Receiver/display unit Power supply (Infrared remote control) 220-240 V 220 V 50Hz 60Hz Note 4 Note 3 Input from outside Note 1 Transmission wiring centralised remote control...
  • Page 13: Sound Data

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Sound data 9 - 1 Sound level data FXHQ-MA Sound pressure level - 220V Model Sound power level Measuring location FXHQ32MA FXHQ63MA FXHQ100MA NOTES Reference acoustic pressure 0 dB = 0.0002 μbar. Measuring place: anechoic chamber.
  • Page 14: Sound Pressure Spectrum

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Sound data 9 - 2 Sound pressure spectrum FXHQ32MA 4D035301 FXHQ63MA 4D035302 Approximate threshold Approximate threshold hearing for continuous hearing for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) FXHQ100MA 4D035303 Approximate threshold...
  • Page 15: Air Flow Pattern

    • Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE Air flow pattern FXHQ100MA Heating Air velocity distribution center air blow 2.5m/sec 1.5m/sec 0.5m/sec Heating Temperature distribution center air blow ® • VRV Systems • Indoor Units...
  • Page 16 Specifications are subject to change without environment. This challenge demands the eco design prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or and development of a wide range of products and an indirect damage, in the broadest sense, arising from or related to the use energy management system, resulting in energy and/or interpretation of this publication.