Unit Startup cont.
f. Energy monitoring can be read on any of the
following components:
i. AID Tool – instantaneous information only
ii. Symphony Web Portal via AWL
device connected to Aurora
Refrigerant Monitoring (optional sensor kit)
The optional Refrigerant Monitoring Kit includes two
pressure transducers, and three temperature sensors,
heating liquid line(FP2), suction temperature and
existing cooling liquid line (FP1). These sensors allow the
measurement of discharge and suction pressures, suction
and liquid line temperatures as well as superheat and
subcooling. This information will only be displayed on
the AID Tool. Ensure the Refrigerant Monitoring has been
setup by accessing the 'Sensor Kit Setup" in the AID Tool
and complete the following:
Once sensors are installed for discharge pressure, suction
pressure, suction, liquid line cooling and liquid line heating
no further setup is required.
a. Turn on Unit in Heating or Cooling .
b. Use the AID Tool to view the refrigerant
performance in the 'Refrigerant Monitor' screen.
c. Refrigerant monitoring can be read on any of the
following components:
i. AID Tool – instantaneous information only
ii. WF Web Portal via AWL device
connected to Aurora
Performance Monitoring (optional sensor kit)
The optional Performance Monitoring Kit includes three
temperature sensors, source entering and leaving water,
load leaving water temperature and a field installed water
flow rate sensor. With this kit heat of extraction and
rejection will be calculated. This requires configuration
using the AID Tool for selection of water or antifreeze.
Ensure the Energy Kit has been enabled by accessing
the 'Sensor Kit Setup" in the AID Tool and complete the
following:
a. Select 'Brine' – and then choose Water or
Antifreeze for the proper factor
b. Select 'Flowmeter' to activate the flow sensor
choose the appropriate 3/4 in. (018-025 models),
1 in. (040-075 models), or none.
c. Turn on Unit in Heating or Cooling .
d. Use the AID Tool to view the performance in the
'Performance Monitor' screen.
e. Performance monitoring can be read on any of the
following components:
i. AID tool - instantaneous information only
ii. WaterFurnace Web Portal via AWL device
connected to Aurora.
AFFINITY SINGLE STAGE HYDRONIC INSTALLATION MANUAL
25