Cleaning the nozzle
To Clean the Nozzle
1. Make sure power cord is unplugged. Remove the air
hose from the rear of the spray gun handle.
2. iSpray nozzle only -
a. Remove the adjustment ring (a) carefully from the
connecting nut (b). Loosen the connecting nut.
b. Remove the parts as shown*. Clean all parts with a
cleaning brush and the appropriate cleaning solution.
To reassemble, see the instructions on the next page.
3. Detail Finish nozzle only -
a. Unscrew the nut and remove the air cap and nozzle.
Remove the parts as shown*. Clean all parts with a
cleaning brush and the appropriate cleaning solution.
Reassemble all parts when clean**.
4. Clean the air vent (c) on the suction tube with a soft
bristled cleaning brush.
5. Push the tab below the trigger, twist and separate the
spray gun from the handle.
Clean the rear of the nozzle (d) with the appropriate
cleaning solution. Use a thin layer of petroleum jelly to
lubricate the O-ring (e).
2b
5
© Wagner Spray Tech - All Rights Reserved
Cleanup (continued)
3a
* Nozzle seal
The nozzle seal may become
stuck inside the iSpray or Detail
Finish nozzle when the nozzle
(e)
is removed. If this occurs, make
sure to pull it out.
(d)
1
2a
(b)
(a)
4
**
It is important that the nozzle
seal inside the nozzle be re-
installed properly. Make sure the
cup side of the seal (the side with
the groove) is facing out towards
the front of the nozzle. Improper
installation will cause leakage.
Groove