4.2.7
New proportional flow meter
The turbine announces in real time the possible variation of flow and by means of the probes, the regulation
is modified instantaneously to have always constant temperatures.
In DHW mode, with a water flow >1.6l/min, the turbine give the information to the electronic to start ignition phase.
It's possible to remove it easily by the front without using any tool.
Page. 50 of 63
A
B
Reed sensor
8
Flow regulator (optional) 8/10lt – 24/28kw
A
Flow meter/filter cold water inlet container
B
C Turbine
D Flow meter cap
C
LEGEND
D