    Replacement Celtic boiler by TALIA..................31 3.4.2 Replacement Centora boiler by TALIA................. 32 3.5 COMPETITORS REPLACEMENT ....................33 3.5.1 Replacement SOUNIER DOUVAL boiler by TALIA .............. 33 3.5.2 Replacement ELM GVM boiler by TALIA ................33 3.6 ELECTRICAL CONNECTIONS......................34 3.6.1 Installer zone .........................
  • Page 3 4.2.1 Open chamber overview......................45 4.2.2 Sealed chamber overview ..................... 46 4.2.3 Hydraulic diagram........................47 4.2.4 Hydraulic circuit ........................48 4.2.5 Hydraulic assembly ....................... 49 4.2.6 By pass ..........................49 4.2.7 New proportional flow meter....................50 4.2.8 Hydraulic group maintenance....................51 4.2.9 Combustion group CF ......................
  • Page 4: Value Propositions

    1 VALUE PROPOSITIONS The new TALIA by Chaffoteaux is the result of a careful analysis of the installers and service technicians needs in order to make their job easier. EASY TO SELL The result is the TALIA boiler, the solution that every customer will choose in terms of easiness of use and its ability to totally satisfy every comfort needs.
  • Page 5: Easy To Sell

    The TALIA boiler and its features make the offer attractive for the installer for any requirement Design & easy interaction A new design, the materials quality and the attention to aesthetic details allow installing TALIA in every place, also the most sophisticated.
  • Page 6: Multilevel Interface

    2.1 MULTILEVEL INTERFACE Different level of accessibility: Different level of accessibility: A first level with two simple encoders A second level for main user functions to set the standard temperature of A third level to access to the complete set Central Heating and Domestic Hot of parameters by Menu Water...
  • Page 7: Display Description

    2.2 DISPLAY DESCRIPTION The new LCD display enables the end user to check the operating status of the boiler at any time. Principal informations are displayed on the display for a better comprehension of operation and adjustments of the boiler. Following, the principal informations displayed on the display for a better comprehension of operation and adjustments of the boiler.
  • Page 8: Functioning And Diagnostic Zone

    2.2.2 Functioning and diagnostic zone LEGEND Indication : menu setting, temperature, default code Reset requested Technical assistance requested Flame indication and power used Heating functioning and temperature level setting Domestic hot water functioning and temperature level setting Clear text for all information Comfort function activated •...
  • Page 9 • Burner flame symbol and relative power level Whenever the burner is producing a flame, the flame symbol appears on the display. The power level at which the boiler is operating is visualised underneath this symbol. • “Heating” operating mode Operation in “Heating”...
  • Page 10: Peripherals Control

    2.2.3 Peripherals control LEGEND Thermoregulation activated Installation with solar panels Info menu • Temperature control functions When the SRA function is activated the boiler automatically recognizes whether a Room Sensor, an Outdoor Sensor or a Clima Manager is connected to the system, adjusting its operation for getting the best efficiency and comfort.
  • Page 11: Information System

    2.3 INFORMATION SYSTEM The simple and practical key information is very useful for the customer and the service after sale Simply by pressing the “INFO” button, the To move from one piece of information to the end user may immediately view a whole next, press again the “INFO”...
  • Page 12: Self-Check Function

    2.4 SELF-CHECK FUNCTION TALIA boiler monitors its own functions and operation status by means of a latest-generation self-check system. The display clearly indicates any anomalies and suggests what to do in the simplest way. It also helps the Technical Service to find the cause of the fault showing an error code, together with an explanation of the type of malfunction.
  • Page 13: Antifreeze" Function

    2.5 “ANTIFREEZE” FUNCTION TALIA boiler is fitted with an Anti- Freeze Protection system for the central heating and the hot water systems. THIS FUNCTION DISABLE ANY HEATING REQUEST. In order to activate it, to repeat press key MODE until that the...
  • Page 14: Dhw Comfort

    2.6.1 DHW performances & certification The hot water production represents the most important value for any boiler and the TALIA has achieved successfully the best level according to EN13203 – part 1 (performance of DHW delivery) in terms of: •...
  • Page 15: Dhw Timer Program

    2.6.3 DHW timer program A saving even more important and subsequently achievable through the weekly DHW programming, built in on the boiler which allows the comfort customizing according to the real need of the customer. A new function that allows setting the DHW weekly timer integrated This function permit to maintain the temperature of the plate heat exchanger for shorter DHW waiting time.
  • Page 16: Solar Predisposition

    2.7 SOLAR PREDISPOSITION Natural circulation solar or centralized solar installation Serie solution with combi boiler & forced circulation Parallel solution with heating only boiler & forced circulation Page. 16 of 63...
  • Page 17: Heating Comfort

    2.8.1 Heating performances & certification In line with the most severe European standard in term of energetic efficiency, Talia is certified *** according to the European standard 92/42/EEC, one certificate which offer also a guaranty of saving. This result thanks to the quality of the components and the intelligence of the boiler capable to optimize the performances of the combustion &...
  • Page 18 Comfort Saving Depending on the different installation configuration level level Basic with room thermostat (on/off) Climatic with external probe & room thermostat on/off Ambient ++++ ++++ with modulating room sensor Complete ++++ +++++ thermoregulation The new SRA function assures to reach the following results: Maximum personalisation Best efficiency Maximum comfort...
  • Page 19: Built-In Weekly Timer

    24-hour programming Controlling 2 zones An heating system which has been divided into two zones is shown. TALIA boiler is able to control timer programming (intervals of 15 minutes) and weekly programming an independent and specific way for each programme.
  • Page 20: Msi Function: Acoustic Comfort

    But not only ! Because in such a way TALIA guarantee a non comparable silence thanks to the MSI function (MultiSoft Ignition), which allows the installation in any place in the house. The ignition is done with a maximum of 3 attempts at different power level to ensure an optimized ignition &...
  • Page 21: Easy To Install

    Also in terms of function TALIA has been designed to help the installers in their activity, the Automatic Air purge” for example facilitates the elimination of any air bubbles present in the heating circuit, optimizing the activity, reducing the time for the completion of the installation and the noise for the end user.
  • Page 22: Overall Dimension

    3.1 OVERALL DIMENSION As accessory * As accessory Central heating flow Domestic hot water flow Gas inlet Domestic cold water inlet Central heating return Page. 22 of 63...
  • Page 23 Page. 23 of 63...
  • Page 24: Hydraulics Connections

    3.2 HYDRAULICS CONNECTIONS All the configurations were imagined before creating a complete range of accessories for the new installation and the replacement. FR MARKET REPLACEMENT KIT Celtic FIRST INSTALLATION TELESCOPIC FLAPS THE PREFITTING KIT DETAILS allows to install easily different type of boiler with or without rear pipes chassis.
  • Page 25: The Solar Kit

    3.2.1 The solar kit A new mixing valve designed to be integrated in the prefitting kit. This device allows to reduced the hot temperature coming from a solar source to ensure the maximum comfort for the client and the complete protection for the boiler. Mixed water (Toward the boiler)
  • Page 26: Flue Connections

    FLUE CONNECTIONS 3.3.1 Open chamber system The open-chamber version enables 125 mm and 130 mm flue gas exhaust piping to be used without adaptors. 3.3.2 Coaxial system 60/100 1. Condensate collection pipe 2. Pressure inspection point positive signal 3. Pressure inspection point caps 4.
  • Page 27 LENGHTS WITH LENGHTS WITH MAXIMUM TYPE OF 60/100 MODELS DIAPHRAGM (m) NO DIAPHRAGM LENGTH EXHAUST (m)) Ø 43 From 1 to 4 from 0,5 to 1 Ø 43 From 1 to 4 from 0,5 to1 Ø 46 From 0,75 to 3 From 0,75 to 0,75 Ø...
  • Page 28: Coaxial System 80/125

    3.3.3 Coaxial system 80/125 LENGHTS WITH MAXIMUM TYPE OF LENGHTS WITH 80/125 MODELS NO DIAPHRAGM LENGTH EXHAUST DIAPHRAGM (m) (m)) Ø 43 from 0,5 to 2 from >2 to 11 Ø 43 from 0,5 to 3 from >3 to 11 Ø...
  • Page 29: Twin Pipes System

    3.3.4 Twin Pipes system For a better flexibility of installation, It allows to connect the air intake pipe to right and on the left Page. 29 of 63...
  • Page 30 TYPE OF LENGHTS WITH LENGHTS WITH NO MAXIMUM 80 + 80 EXHAUST MODELS DIAPHRAGM (m) DIAPHRAGM (m)) LENGTH Ø 80/80 Ø 43 24 kW from 5 to 19 (S1=S2) 19+19 (S1=S2) from 0,5 to 5 (S1=S2) Ø 43 30 kW from 0,5 to 7 from 7 to 24 (S1=S2) 24+24 (S1=S2)
  • Page 31: Old C&M Boiler Range Replacement

    3.4 OLD C&M BOILER RANGE REPLACEMENT All accessories are available for the replacement of old C&M boiler. Hydraulic kit Exhaust flue kit 3.4.1 Replacement Celtic boiler by TALIA Kit installation for Celtic replacement Celtic on the wall Installation of the Celtic removing...
  • Page 32: Replacement Centora Boiler By Talia

    3.4.2 Replacement Centora boiler by TALIA adaptation kit for pipes adaptation kit for exhaust flue Centora on the Installation of the Celtic removing Installation of Installation of the wall preffiting kit with the new Talia tap handing kit from the wall and...
  • Page 33: Competitors Replacement

    3.5 COMPETITORS REPLACEMENT 3.5.1 Replacement SOUNIER DOUVAL boiler by TALIA Only the hydraulics connections need the replacement kit. For this substitution, the exhaust flue doesn’t need any special component. 3.5.2 Replacement ELM GVM boiler by TALIA All accessories are available for the replacement of ELM boiler.
  • Page 34: Electrical Connections

    3.6 ELECTRICAL CONNECTIONS 3.6.1 Installer zone Also for the electrical connections, has been created an installer zone, in Frontal Panel rear side, for an easy access to the PCB box where all the connections with the external devices can be easily done. Remote connections PCB position for e- External clip ins...
  • Page 35: Thermoregulation Device Connections

    3.6.2 Thermoregulation device connections Wired Multizones Wired regulation Modulating manager devices Modulating room sensor Remote control Wired on/off Room devices thermostat Room thermostat External device External probe Wireless External External sensor Wireless device Remote control Wireless Modulating devices Room sensor Room Wireless on/off thermostat...
  • Page 36: Installation Setting & Functions

    3.7 INSTALLATION SETTING & FUNCTIONS 3.7.1 The personalisation Menu The boiler can start & work without any setting. The menu gives the installer the opportunity to personalise every installation (external storage, monozone, multizone, solar …) as preferred. Language, days and time settings Chrono End user •...
  • Page 37: Flue Cleaner Function

    3.7.3 Flue cleaner function This function is used to perform proper boiler combustion analysis and maximum and minimum gas calibration Pressing the button reset for 5 sec will start two possible conditions: Boilers on “winter” mode, the 3 way valve is positioned on “heating”...
  • Page 38: Clip In In 2 Relés

    3.8.1 Clip IN in 2 relés This small pcb represents an easy solution to manage two different devices (pump or valve zones) for: - Big installation with necessity to manage a further pump (it remains unused the second relé) - A double zone installation Furthermore, using the double zones timer integrated in the boiler and two simple room thermostat or room sensor, the installer can give the client a very complete and customized solution with the maximum level of installation easiness.
  • Page 39: Clip In In Solar

    3.8.2 Clip IN in solar Solar installation with natural circulation configuration This configuration ensures the same advantages of the previous Clip IN but furthermore can manage an electrical DHW mixing valve before the boiler to control a possible DHW input by a solar source to protect the boiler and improve the behaviour of the boiler in these conditions (outlet DHW T stability) Page.
  • Page 40 Solar installation with forced circulation configuration in serie A complete forced circulation solar installation management is possible thank to the boiler predisposition and the integration of this small PCB, for serial & parallel configuration There is the possibility to control the solar installation with the connection of the collector sensor, the storage sensor and the DHW outlet temperature that can be controlled in the best way using an external electrical mixing valve with a control directly on the frontal boiler interface Page.
  • Page 41 Solar installation with forced circulation configuration in parallel A complete forced circulation solar installation management is possible thank the boiler predisposition and the integration of this small PCB, for serial & parallel configuration There is the possibility to control the solar installation with the connection of the collector sensor, the storage sensor and the DHW outlet temperature that can be controlled in the best way using an external electrical mixing valve with a control directly on the frontal boiler interface Page.
  • Page 42: Easy To Maintain

    4 EASY TO MAINTAIN TALIA is easy to maintain. Thanks to frontal access for all components, the boiler is able to offer reduced maintenance time and most of the work can be performed without using tools. It is also possible to inspect the burner without having to remove it, and the injector distribution ramp may be accessible from the front of the appliance.
  • Page 43: Diagnostic

    4.1 DIAGNOSTIC The new display fitted in this boiler range is very useful for describe boiler faults. Different indications indicate which type of error it is and what you have to do (reset, no reset …….) A little text describe perfectly the type of error and it is a real benefit for the after sale service to save time. There are two types of errors for malfunctions: - Shutdown (solved by resetting);...
  • Page 44: Msa: Modular System Approach & Boiler Overview

    4.2 MSA: MODULAR SYSTEM APPROACH & BOILER OVERVIEW A modular strategy based on : A functional approach A common and modular structure A common and modular hydraulic group Common layout Common & selected components The best results in terms of easiness & rapidity in the maintenance activity: •...
  • Page 45: Open Chamber Overview

    4.2.1 Open chamber overview LEGEND 1. Flue gas exhaust duct collar Spark generator 2. TTB safety Burner Safety valve 3. Safety thermostat (overheating) 105°C Control panel 4. Primary exchanger flow sensor Modulating circulation pump with automatic deaerator 5. Detection and ignition electrodes Primary exchanger inlet sensor 6.
  • Page 46: Sealed Chamber Overview

    4.2.2 Sealed chamber overview LEGEND 1. Air inlet for twin pipe systems 10. 3-bar safety valve 2. Air pressure switch 11. Control panel 3. Condensate collection pipe 12. Modulating circulation pump with automatic deaerator 4. Safety thermostat (overheating) 105°C 13. Primary exchanger inlet sensor 5.
  • Page 47: Hydraulic Diagram

    4.2.3 Hydraulic diagram LEGEND 1. Primary exchanger Heating system return filter 2. Safety thermostat (overheating) 105°C Pressure gauge 3. Primary exchanger flow sensor Output flow regulator (optional) 4. Burner 3-way diverter valve 5. Ignition electrodes Modulating circulation pump with deaerator 6.
  • Page 48: Hydraulic Circuit

    4.2.4 Hydraulic circuit LEGEND Expansion vessel 3-bar safety valve Primary heat exchanger Hot water flow meter Safety thermostat (overheating) 105°C Modulating circulation pump with deaerator Primary exchanger flow sensor 3-way diverter valve motor Secondary exchanger Primary exchanger inlet sensor Boiler drain valve Page.
  • Page 49: Hydraulic Assembly

    4.2.5 Hydraulic assembly FRONT VIEW LEGEND 1. 3-way diverter valve 8. Electronic hot water flow meter sensor 2. Secondary exchanger 9. Filling tap (no French market) 3. Domestic hot water flow sensor 10. Heating system return filter 4. Hot water from the primary exchanger 11.
  • Page 50: New Proportional Flow Meter

    4.2.7 New proportional flow meter The turbine announces in real time the possible variation of flow and by means of the probes, the regulation is modified instantaneously to have always constant temperatures. In DHW mode, with a water flow >1.6l/min, the turbine give the information to the electronic to start ignition phase. It’s possible to remove it easily by the front without using any tool.
  • Page 51: Hydraulic Group Maintenance

    4.2.8 Hydraulic group maintenance The new Hydroblock designed by Chaffoteaux stands out due to the frontal access to all main components and their removal without the use of tools. These features offer a substantial reduction in maintenance times. COMPONENT DISTINCTIVE FEATURE...
  • Page 52: Combustion Group Cf

    4.2.9 Combustion group CF LEGEND 1. TTB safety Spark generator 2. Burner Manifold 3. Detection and ignition electrodes Primary heat exchanger 4. Gas valve Deflector 5. Gas pipe Page. 52 of 63...
  • Page 53: Combustion Group Ff

    4.2.10 Combustion group FF LEGEND 1. Pressostat 6. Spark generator 2. Burner 7. Manifold 3. Detection and ignition electrodes 8. Primary heat exchanger 4. Gas valve 9. Fan 5. Gas pipe Page. 53 of 63...
  • Page 54: Combustion Group Maintenance

    4.2.11 Combustion group maintenance COMPONENT DISTINCTIVE FEATURE ADVANTAGES Sockets for exhaust flue/air inlet analysis Built into the boiler and accessible Reduction in labour time as the from the outside boiler does not have to be opened Sockets for pression analysis Built into the boiler and accessible Reduction in labour time as the from the outside...
  • Page 55: Boiler Codes

    5 BOILER CODES DIMENSIONS MARKETS CODE MODEL 3650177 TALIA 25 CF N BE 3650178 TALIA 25 FF N BE 3650179 TALIA 30 CF N BE 3650180 TALIA 30 FF N BE 3650181 TALIA 25 CF N IT 3650182 TALIA 25 CF B/P IT...
  • Page 56: Accessory Codes

    6 ACCESSORY CODES 6.1 INSTALLATION ACCESSORIES DESCRIPTION • “BARRETTE” KIT 3678350 IT MARKET FR MARKET 3678360 3678364 BE MARKET 3678354 ES/PT MARKET • PIPES FOR NEW INSTALLATION 3318323 “BARRETTE” KIT IT MARKET • PIPES FOR “BARRETTE” KIT 3318253 (with rear chassis) FR MARKET •...
  • Page 57: Termoregolation Interfaces

    6.2 TERMOREGOLATION INTERFACES DESCRIPTION • BUS INTERFACE 3318330 It allows to connect all the modulating devices • ‘CLIP IN’ 2 ZONES HIGH INTERFACE 3318242 To manage a Central Heating (two zones high temperature) • ‘CLIP-IN’ INTERFACE WITH 3318249 MIX VALVE For Domestic Hot Water •...
  • Page 58: Termoregolation Accessories

    6.3 TERMOREGOLATION ACCESSORIES DESCRIPTION WIRED WIRELESS 3318298 3318303 • REMOCOM Allows to manage all the boiler’s functions, shows the error codes and manage 2 Central Heating zones. • ROOM SENSOR 3318302 3318304 Allows to select the Central Heating mode : set the room temperature. Wire Wireless : set and show the room temperature _____...
  • Page 59 • SIGNAL RECEIVER wireless 3318308 Allows the communication between the boiler and the T-CONTROL. 3318300 • ROOM THERMOSTAT on/off wired (RTw) Allows the room temperature thermoregulation. 3318306 • SIGNAL REPEATER wireless (RPws) Allows the communication between the boiler and the device when the distance is too big. Page.
  • Page 60: Hydraulic Accessories

    6.4 HYDRAULIC ACCESSORIES DESCRIPTION • MONO ZONE KIT 3318286 Box mono-zone Hight temperature Kit + Clip in A • MULTI ZONE KIT 3318287 Box two zone Hight temperature Kit + Clip in A • MULTI ZONE KIT 3318346 Box three zone Hight temperature kit •...
  • Page 61 • SOLAR KIT 3678290 Valve + solar sensor • SOLAR KIT Electrical mixing valve + clip in B 3678296 • SOLAR KIT 3678297 Electrical mixing valve + clip in C + sensor collector + sensor boiler • REPLACEMENT KIT 3678387 Sounier Douval •...
  • Page 62: Technical Data

    7 TECHNICAL DATA 7.1 OPEN-CHAMBER Model Name 25 CF 30 CF General CE certification (pin) comments B 11bs B 11bs Boiler type Max./min. nominal heat input central heating (Hi) 25,8/11,0 29.6/13 Max./min. nominal heat input central heating (Hs) 28,6/12,4 Max./min. nominal heat input D.H.W. mode (Hi) 27/11 31.1/13...
  • Page 63: Sealed-Chamber

    7.2 SEALED-CHAMBER 35 FF Model Name 25 FF 30 FF General DRAFT comments CE certification (pin) C 12 -C 32 -C 42 -C 52 -C 62 -B 22 -B 32 Boiler type Max./min. nominal heat input central heating (Hi) 25,8/11 30/13 34,4/14 Max./min.