4 EASY TO MAINTAIN

TALIA is easy to maintain. Thanks to frontal access for all components, the boiler is able to offer reduced
maintenance time and most of the work can be performed without using tools.
It is also possible to inspect the burner without having to remove it, and the injector distribution ramp may be
accessible from the front of the appliance.
The digital interface creates a link between the Assistance Service and the end user, in fact the data and
telephone number of the relevant Assistance Centre can be entered so that the user may then read it from
the display using the "INFO" button.
Furthermore, when an operating anomaly occurs, the display shows the corresponding error code with an
explanation and the information which may then be relayed to the Assistance Service so that the technician
is well prepared with the necessary material when coming to repair the appliance.
MAIN ADVANTAGES FOR THE SERVICE TECHNICIANS
All components may are accessible from the front;
a.
Maintenance times are reduced;
b.
Maintenance work can be performed on most of the components inside the boiler without the use of tools;
c.
Front access to the injector distribution ramp which facilitates gas conversion;
d.
The burner can be inspected and cleaned without being removed;
e.
Ceramic single block for positioning the ignition electrodes;
f.
Temperature contact sensors;
g.
Multifunctional digital interface with the following integrated functions:
h.
display of error codes;
informative text which makes controlling the boiler extremely simple;
display of central heating system pressure;
display of the ON burner and corresponding power level;
combination of the boiler with solar panels;
outdoor temperature monitoring °C (with outdoor sensor connected);
indoor temperature monitoring °C (with indoor sensor connected);
display of the number of months until the next scheduled maintenance operation.
Modulating circulation pump which varies its speed according to the requested flow temperature;
i.
Automatic bypass;
j.
Anti-freeze protection system for the heating and hot water circuit;
k.
Limescale protection;
l.
Circulation pump and three-way valve anti-sticking system;
m.
"AIR PURGE" function facilitates the elimination of any air bubbles present in the heating circuit;
n.
"CHIMNEY SWEEP" function enables flue gas analysis;
o.
Inspection points for flue gas analysis accessible from the outside;
p.
Flue gas pressure switch signal points accessible from the outside;
q.
Heating return filter;
r.
Domestic cold water inlet filter;
s.
Heating system drain tap.
t.
Page. 42 of 63