Transfer
The transfer can be adjusted to Low, Medium, or High. The default setting is Medium.
Select Back to return to Diagnostics Menu.
Print Contrast
The print contrast can be adjusted to Low, Medium, or High.
The default setting is Medium. Select Back to return to Diagnostics Menu.
Charge Roll
The charge roll can be adjusted to Low, Medium, or High.
The default setting is Medium. Select Back to return to Diagnostics Menu.
Gap Adjust
The setting adjusts the minimum gap between sheets. Increasing this value may reduce
curl of some printed media and eliminate some output bin stacking problems. However,
increasing this value also results in slower overall performance, measured in pages per
minute. The range of values is 0 to 255, and the default value is 0. Select Back to return
to Diagnostics Menu.
Auto Dark Adjust
The settings are Enable and Disable.

REPORTS

Menu Settings Page
This enables you to print the Menu Settings Page. The report prints the Diag Menu to
include:
Registration
Print Tests
Hardware Tests
Duplex Tests
Input Tray Tests
Output Bin Tests
Device Tests
Printer Setup
EP Setup
Reports
Event Log
Development Menu
Scanner Tests.