Installing the Battery
1. Position battery in the tray with the terminal posts
opposite from the hydraulic tank
2. Install the positive (red) battery cable to the positive
(+) battery terminal.
3. Install the negative (black) battery cable and ground
wire to the negative (-) battery terminal.
4. Secure the cables with 2 bolts, 2 washers, and 2
locknuts
(Figure
61).
5. Slide the red terminal boot onto the positive (+) battery
terminal.
6. Install the clamp and secure it with the wing nut
61).
Charging the Battery
WARNING
Charging the battery produces gasses that can
explode.
Never smoke near the battery and keep sparks and
flames away from battery.
Important: Always keep the battery fully charged (1.265
specific gravity). This is especially important to prevent
battery damage when the temperature is below 0°C
(32°F).
1. Charge battery for 10 to 15 minutes at 25 to 30 A or
for 30 minutes at 10 A.
2. When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the charger
leads from the battery posts
3. Install the battery in the machine and connect the
battery cables; refer to
Note: Do not run the machine with the battery
disconnected; otherwise, electrical damage may occur.
(Figure
61).
(Figure
(Figure
62).
Installing the Battery (page
1. Positive battery post
2. Negative battery post
Servicing the Fuses
The electrical system is protected by fuses. It requires no
maintenance, however, if a fuse blows check the component
and circuit for a malfunction or short.
1. The fuses are located on right console next to the seat
(Figure
63).
2. To replace the fuses, pull out the fuse to remove it.
3. Install a new fuse
46).
1. Optional accessory (15 A)
2. Charge (25 A)
3. PTO (10 A)
46
Figure 62
3. Red (+) charger lead
4. Black (-) charger lead
(Figure
63).
Figure 63
4. Main (25 A)
5. Console